3. Delay protection function of compressor
This unit offers restart protection to compressor. Except that the compressor may start immediately when the unit is
energized first time, there is 3-minute delay re-start protection after compressor is shut down.
4. C
oil and room temperature sensor failure:
1) Detect sensor failure at the beginning of power-on or power-on state
2) When a sensor failure is detected at the beginning of power-on, it will immediately enter the failure state. If it
returns to normal at this time, it will enter the standby state;
AIR CONDITIONER USE
IMPORTANT: If the air conditioner has been tilted on its side, wait 24 hours before turning on the air conditioner to allow
the oil to return to the compressor. This will prevent the air conditioner from failing prematurely.
Hold handles on side panels to move the unit in upright position.
NOTE:
Do not hold the louver.
Make the unit in the upright position whatever handling or moving it.
Drain the water in the unit completely to prevent water leakage and wet the floor or carpet before handling or
moving the unit.
DRAIN THE INTERNAL WATER
You will need a small pan to catch the water coming out of the water tank. Once the water tank is empty, the unit will
resume operation within a few minutes.
MANUAL DRAINAGE
1. Once the unit shuts down upon water-full, turn off the unit and then unplug.
2. Put the tray below the water outlet at the back of the unit.
3. Screw off the drain cover, unplug the water stopper for water flow into the tray.
4. Plug in stopper and screw the drain cover tightly onto water outlet after drainage.
Notes:
Protect the drain cover and water stopper properly.
Move the unit carefully to avoid the leakage it is necessary.
Tilt the unit slightly backwards when draining.
Block the drain hole as soon as possible before the tray is full if it cannot
hold all water in the unit to prevent the water leakage and wet the floor
or carpet.
Water stopper and drain cover must be tightly installed, to avoid new
condensate to wet the floor or carpet when the unit re-starts working.