System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model UKF8001AXX
Specifications
Service Flow Rate (Maximum) .............................................0.78 GPM (2.9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum) ......750 gallons/2838 liters
Maximum Operating Temperature .....................................100° F/38 ° C
Minimum Pressure Requirement ........................................35 psi/241 kPA
Minimum Operating Temperature ......................................33° F/1 ° C
Maximum Operating Pressure .............................................120 psi/827 kPA
a3M Compa¢_ p
1000 Apollo Road
Eagan, Minnesota 55121-2240
651.450.4913
EPA EST #35917-MN-1
Performance Data
Parameter
Chlorine
T&O
Particulate**
100834/B
USEPA
MCL
Standard No. 42: Aesthetic Effects
Influent
Challenge Concentration
2.0 mg/L _+10%
Min. Required
Reduction
50%
Influent
Average
1.88 mg/L
5,700,000 #/ml
Effluent
Average Maximum
_0.05136364 mg/L 0.06 mg/L
30,583 #/nil 69,000 #/ml
% Reduction
Average Minimum
>9726% 96.84%
99.52% 98.94%
at least 10,000 particles/ml 85%
Parameter
Turbidi b,
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury at pH 6.5
Mercury at pH 8.5
Atrazine
Benzene
Carbofuran
1,4-Dichlolobenzene
Lindane
Toxapbene
USEPA
MCL
1 NTU**
99.5% Reduction
99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.003 m_iL
0.005 m_iL
0.04 m g/L
0.075 m g/L
0.0002 m g/L
0.003 mg/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11 ± 1 NTU***
Minimum 59,OOO/L
107108 fibers/L; fibers >10 nlicron/eters in length
0.15 mg/L + 10%
0.15 mg/L + 10%
.006 mg/L _+ 10%
.006 mg/L _+ 10%
0.009 m0/L + 10%
0.015 m(iL _+ 10%
0.08 m g/L _+ 10%
.225 m g/L _+ 10o/o
0.002 m g/L + 10%
0.015 ± 10%
Influent
Average
10.7 NTU
166,500 #/L
155 MF/L
0.153 mg/L
0.150 mg/L
0.006 mg/L
0.006 mg/L
O.OO9 m_)/L
O.014 nl_iL
0.081 m g/L
0.208 m g/L
0.002 m g/L
0.015 mg/L
Effluent
Average Maximum
0.31 NTU .049 NTU
<1 #/L <1 #/L
<1 MF/L <1 MF/L
<.001 mg/L <.001 mg/L
<.001 mg/L <.001 mg/L
0.0003 mg/L 0.0005 mg/L
0.0008 mg/L 0.0015 mg/L
<0.002 mg/L 0.002 mg/L
0.0006 mq/L 0.0011 nyiL
<0.001 mg/L <0.001 mg/L
<0.0005 m g/L <0.0005 m g/L
0.00O mg/L <0.0001 mg/L
<0.001 mg/L <0.001 mg/L
%Reduction
Average Minimum
97.09% 95.20%
>99.99% >99.99%
>99.99% >99.99%
>99.35% >9929%
>99.33% >9929%
95.70% 90.91%
86.22% 75.93%
76,99% 75.31%
95.71% 92.14%
98.74o/o 98.46o/o
99.76o/o 99.74o/o
98.72% 96.50o/o
92.97% 91.67%
Min. Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mq/L
0.04 mq/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of
68 °+5° F [20 ° +3°C]
** Measurement in Particles/nil. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water
treatment needs.
DO NOT use this product where water is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. System certified for cyst reduction may be
used on disinfected water that may contain
filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE WITH THE STATE AND LOCAL
LAWS AND REGULATIONS.
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Clllorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
Tested and certified by NSF IntemaUonal against ANSI/NSF Standards 42 & 53
in models UKF8001AXX-750 for the reduction of:
Standard No. 53: Health Effects
Cbenlical Reduction Unit
Lead, Atrazine, Lindane, Benzene,
Carbofuran, 1,4- DicllloT obenzene,
Mercury & Toxapllene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
The PuriClean :_II retractable water filtration system
uses a UKF8001AXX replacement cartridge. Timely
replacement of filter cartridge is essential for
performance satisfaction from this filtration system.
Please refer to the applicable section of your Use &
Care Guide for general operation, maintenance
requirements and troubleshooting.
This system has been tested according to ANSI/NSF 42
and 53 for reduction of the substance listed above. The
concentration of the indicated substances in water
entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving
the system, as specified in ANSI/NSF 42 and 53. 18