- 7 -
corners of the charbroiled bottom, ensure sufficient space for ventilation;
Adjustable stainless steel legs to make the equipment level, and get the
same level with other series of the same stove; Please lift the equipment
rather than drag if you need to move it;
Supplied gas pressure regulator is factory set at 4”Natural Gas W.C,
and 10”L.P. Gas W.C;
The equipment can only be placed on the incombustible counter top, and
keep a distance of at least 6 inches(152mm) to equipment’s both sides and
back, and keep a distance of at least 4 inches(102mm) to the bottom;
Do not put anything around the equipment, and on the counter top and bottom,
in order to avoid influencing combustion and air circulation;
Leave enough distance in front of the equipment to take apart the control
panel. All major parts, in addition to the burner remove from the front
intake-tube;
It may be necessary to adjust the balance of air input by authorized and
licensed technicians;
Thread glue must be resistant to the action of liquefied petroleum gases.
Warning! Use soap water or testing instrument to test whether piping joint
leaks or not before using, and forbid using an open flame to test!
After installing completely, you should check gas supply pressure. Use
a pressure gauge which is equipped with liquid (such as U-type pressure gauge,
the minimum value is 0.1mbar) or a digital pressure gauge to test. Steps are
as following:
●Remove top panel, and needle type pressure
joint screw arbor (Fig.1), then slip
rubber tube of pressure gauge over needle
type pressure joint;
●Start the equipment in accordance with the
instructions, measuring gas supply
pressure (dynamic pressure) in the work
state;
●Access to the equipment if measured data
within the limits of Table 1, otherwise,
you will need to adjust gas pressure
regulating valve or contact gas supplier
to bargain; Fig.1
Unplug pressure gauge after you accomplish pressure testing, then
install needle type pressure joint screw arbor.
Important: must screw
joint screw arbor, to prevent gas escape!
6.2、Debugging
It’s very important to debug the new stove. Through the comprehensive
system test of equipment, we can ensure function and safety performance of
products. Discovering any potential problems before use (such as