Turn the burners on about 15-20 minutes before broiling for preheating,
according to the cooking requirement to adjust the flame size.
Notice: When first preheating, the furnace will smoke above. This is
caused by protective lipids on the grates and other parts are heated, it is
normal, and it will be eliminated after the power up to the maximum for burning
an hour.
8.5、Exchange main fire nozzle to switch gas source
Remove control panel, cooking grates, the pilot light head, and burner,
remove main fire nozzle with proper open spanner, exchange nozzle of another
gas source, then screw it. Reinstall burner, the pilot light head, cooking
grates and control panel in proper order.
Caution: Each main fire orifice of the burner has been installed before
delivery, normal use without adjustment but only switching gas. Adjust only
by authorized and licensed technicians. When you converse the gas source,
exchange the corresponding pressure maintaining valve which installed on air
intake. See 2 in P17.
8.6、Adjust air input
Remove control panel, unscrew damper solid screw(Fig.6), revolve damper
left to right (Fig.7), meanwhile, observe flame, to adjust an appropriate
opening degree. Then screw damper solid screw, make sure the equipment will
not get loose in the process of moving and translation. Reinstall control
panel.
Caution: Each burner damper has been adjusted before delivery (once air
input), normal use without adjustment but only switching gas. Adjust only
by authorized and licensed technicians.
Fig.5 Fig.6 Fig.7
9. Cleaning and Maintenance
Do not use any abrasive or flammable detergent to wipe;
Do not hose down, immerse or pressure wash any part of the cooker,
excluding the catch tray;
Do not use abrasive cleaning matters to wash, even not use corrosive
Loading ...