GE - General Electric AZ55H09DACM1 Official GE Zoneline Air Conditioner

User Manual - Page 16

For AZ55H09DACM1.

PDF File Manual, 24 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation Instructions
265 VOLT ELECTRICAL SUPPLY
[] REINSTALL JUNCTION BOX
Reinstall the junction box by engaging the tab at the
lo_vr rea_, aligning the screw hole at the top and
driving the one screw tmfil secure. Be sure that all
wire leads are inside the box and not pinched
between the box and the refit. The green insulated
ground wire fl'om the refit MUST be connected to
the branch circuit gromM wire.
Make all wire connec6ons by using appropriate
LrlAisted electrical connectcn_ and techniques
(black to black, white to white and green to green).
[] REINSTALL JUNCTION
BOX COVER
1 Caretifllv m(k all wires and
c(mnections back inside the
jtmcfion box. Be sm'e there
are i1o loose connections or
stray mfinsulated wires
exposed.
2 Place thejtmcfion box cover
in place. Replace the two ,r
screws I'elIloved earlier and
tighten secm'elv:
3 Discard the tmused portion of the plug and
the cordset.
POWER CONNECTION CHART
230/208 Volt
Power
Supply Kits
RA_K3152
RAK3202
RAK3302*
Wall Plug Heater Wattage
Configuration Circuit Protective Device @ 230/208 Volts
Tandem ] 15 Amp Time Delay Fuse or Breaker 2.55/2.09 K\_
I
Perpendicular 20 Amp Time Dela'_ Fuse or Breaker . .4:/2.82 K\\
i,arge Tandem 3(1 Amp Time Delay Fuse or Breaker 5.00/4.10 tKA4
265 Volt
Power
Supply Kits
Wall Plug
Configuration
Circuit Protective Device
Heater Wattage
@ 265 Volts
RAK5152
RAK5172
RAK5202
RAK5302*
Does Not Apply
Does Not Apply
Does Not Apply
Does Not Apply
15 Amp Time Delay Fuse or Breaker
15 Amp Time Delay Fuse or Breaker
20 Amp Time Delay Fuse or Breaker
30 Amp Time Delay Fuse or Breaker
1.7 KW
3.0 KW
3.7 KW
5.0 I4A4'
* Not recommended for use on 7000 BTUH milts.
16
Loading ...
Loading ...
Loading ...