16 17INSTALLATION
INSTALLATION INSTRUCTIONS
WARNING
WARNING
This must be read! The laws, ordinances, directives and
standards in force in the country of use are to be followed
(safety regulations, proper recycling in accordance with
the regulations, etc.)
TIPS & INFORMATION
IMPORTANT
Installation may only be carried out by a qualified
electrician. The minimum distances to other appliances
and units are to be observed.
Anti-shock protection must be provided by the
installation, for example drawers may only be installed
with a protective floor directly underneath the appliance.
The cut surfaces of the worktop are to be protected
against moisture using a suitable sealant. The sealant seals
the appliance to the work top with no gap. Do not use
silicon sealant between the appliance and the work top.
Avoid installing the appliance next to doors and under
windows. Otherwise hot cookware may be knocked off
the rings when doors and windows are opened.
WARNING
WARNING
Risk of injury from electrical current.
The electrical mains terminal is live.
Make electrical mains terminal free of voltage.
Follow connection schematic.
Observe electrical safety rules.
Ensure anti-shock protection by installing correctly.
The appliance must be connected to the electrical
supply by a qualified electrician.
Loose and inappropriate plug and socket connections
can make the terminal overheat.
Have the clamping connections correctly installed by
a qualified electrician.
Use strain relief clamp on cable.
WARNING
WARNING
The surface temperature exceeds 95°C. To avoid a
hazard, underbench access must be restricted.
Electrical Connection
Before connecting, check that the nominal voltage of the
appliance, that is the voltage stated on the rating plate,
corresponds to the available supply voltage. Also check
the power rating of the appliance and ensure that the
wire is suitably sized in accordance with AS/NZS 3000
wiring rules to suit the appliance power rating. The rating
plate is located on the lower casing of the hob. Means for
disconnection must be incorporated in the fixed wiring in
accordance with AS/NZS 3000 wiring rules. The hob is
to be connected to the mains using a device that allows
the appliance to be disconnected from the mains at all
poles with a contact opening width of at least 3 mm, eg.
automatic line protecting cut-out, earth leakage trips or
fuse. If this appliance’s mains cable is damaged, it must
be replaced by a special cable (type H05RR-F Tmax
90°C; or higher). The connection must be carried out as
shown in the diagram. The connecting links should be
fitted according to the appropriate connection diagram.
The earth lead is connected to terminal. The earth lead
must be longer than leads carrying electric current. The
cable connections must be made in accordance with
regulations and the terminal screws tightened securely.
Finally, the connecting cable is to be secured with the
mains cable cleat and the covering closed by pressing
firmly (lock into place). Before switching on for the first
time, any protective foil or stickers must be removed from
the glass ceramic surface.
Connection cable
Use the correct mains cable of type H05RR-F Tmax
90°C (or higher) for a single phase or two phase
connection.
Replace the damaged mains cable with a special
cable (type H05RR-F Tmax 90°C or higher) 3 x
2.5mm
2
with an all-pole 25A breaker. For WHC633BD
& WHC933BD. And 3X4mm
2
with an all-pole 32A
breaker for WHC643BD & WHC943BD. Speak to your
local Service Centre.
The earth cord (green/yellow cable) must be 2cm
longer than phase and neutral cable (blue and brown
cables).
The cable conditions must be in accordance with
regulations and the terminal screws tightened
securely.
The connecting cable is to be secured with the mains
cable cleat and the covering closed by pressing firmly
(lock into place).
Before switching on for the first time, any protective
foil or stickers must be removed from the glass
ceramic surface.
WARNING
WARNING
Once connected to the mains supply check that all
cooking zones are ready for use by briefly switching each
on in turn at the maximum setting.
A duplicate rating label is supplied with this unit. For
easy identification of this unit after installation, stick it
to a readily available surface adjacent to the cooktop.
Sticking on the seal
Clean the worktop around the cutout area.
Stick the single-sided adhesive sealing tape provided
on the underside of the hob around the outside edge
ensuring that it is not stretched. The two ends of
the tape should join in the middle of one side. After
trimming the tape (allow it to overlap by 2-3 mm),
press the two ends together.
ASSEMBLY
ASSEMBLY
WARNING
WARNING
Surface temperatures of base exceed 95°C, under bench
access must be restricted by use of non-combustible
barrier on installation
WHC633BD & WHC643BD
560+1
600
R5
490+1
WHC943BD
880+1
R5
490+1
600
min.
50mm
min.
600mm
NOTE: The clearance must meet or exceed the minimum
recommended for both the rangehood and cooktop.
Refer to the rangehood installation manual.