Performance Data Sheet
GE SmartWater Filtration System
GWF 06 Cartridge
Health Claim Performance Certified by NSF/ANSI*
100%safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter
( hlorine
T&O
Pmfioflate** 200,000
Parame_r
USEPA
MCL
USEPA
Turbidi/y
Cys/s
I,ead at PH 6.5
I,ead at pH 8.5
IJndane
Auazine
2,4-D
Asbestos
Influent
Challenge
1.9 ppm
Effluent
Average
0.02 ppm
3,978
Standard No. 53: Health Effects
Influent Effluent
Maximum
0.05 ppm
7,800
% Reduction
Average Minimum
98.90% 97.37%
98.00% 96.10%
% Reduction
MCL
1 NTU***
9{!.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppin
99%
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0.272 ppm
690 MFI !ml
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.0264 ppm
0.32 MFL/ml
Tested ushTga flow rate of 0.5gpm; pressure of 120psig; pH of Z 5+_O.&temp. of 20+_25C
** Measurement in particles/ml
*** NTU = Nephelemetric Units
Maximum
0.1 NTU
55
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.080 ppm
1.2 MFL/ml
Average
99.71%
99.97%
9{1.37%
98.8O%
91.{)3%
76.1{)%
90.29%
99.95%
Minimum
{!{!.5{!%
99.95%
99.37%
97.13%
91.93%
64.28%
70.58%
{)9.82%
Operating Specifications
i_ ( apa(i/y: certified ti)r up to 500 galhms (1895 l)
i2 Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
>_Temperature: 33-100 F (0.6-38 C)
_i:_Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
i2 Flush new cartridge at tull flow tot 3 mim_tes to purge out trapped air.
;i:_Replace cartridge when flow becomes tot) slow; at least every six mouths.
Special Notices
i_;:Installation instructions; parts and service availability; and standard warranty are included with the product when shipped.
>_This drinking water system must be maintained according to mamflhc/urer's instructions, including replacement of
fiher cartridges.
N Do uot use with water that is microbiologically uusafe or of unknown quality without adequate disinte(tiou before or after
the system. Systems certified ti)r cyst reduction may be used on disinfected water that may contain fiherable cysts.
i¢_The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
N Check ti)r compliance with the state and local laws and regulations.
S?slcm Tested and Cer/ificd by NSF lnternad(mal against ANSI/NSF
Standard 42 & 53 fin Ihe reduction ()f:
Standard No. 42: Aesthetic Effects
Chemical knit
Taste and ()dot Reducti(m
Chlorine Reduction, (lass 1
Mechanical l,ihration It nit
Particulate Reducd()n, (lass I
Standard No. 53: Health Effects
Chemical Rcdncti(m [ nit
lvad and Au'azine Reduction
IJndane and 2,41) Reduction
Mechanical l,ihration It'nit
Turbidity Reduction
Cysl and Asbesu)s Rcducti(m