128470781 Gerni Classic 130.3 Series 1885 PSI Pressure Cleaner

User Manual - Page 15

For 128470781.

PDF File Manual, 24 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
15Original Instructions
6 After using the pressure washer
See the pictorial quick reference guide – storing the high pressure washer.
The high pressure washer should be stored in a frost free room! Should the machine by a mis-
take be frozen, it will be necessary to check it for damages.
6.1 Stopping the high pressure washer
C1 Shut off the water supply and activate the trigger of the spray handle and let the machine
run until no more water runs out of the nozzle. This will wash out water hose, high pres-
sure hose, spray lance and nozzles.
C2 Stop the machine,pressing the start/stop switch to position "0".
C3 Unplug the machine from the power supply socket.
IMPORTANT!
To avoid accidents, the electric cable and the high pressure hose should always be wound up
carefully.
C4 Wind up the electric cable on the dedicated cable hook (14).
C5 The high pressure washer comes in two models: A) with hook for storage of high pres-
sure hose (14) - B) with a hose reel (13).
C6 Rinse the spray lance, nozzles and the foam sprayer after use.
C7 Place spray handle, lance, nozzles, foam sprayer in the holders on the high pressure
washer. The nozzle cleaning tool and a Click & Clean brush can also be stored on the
product.
7 Maintenance
See the pictorial quick reference guide - maintenance.
To ensure a long and problem free working life of the high pressure washer, please take the
following advices:
Wash out water hose, high pressure hose, spray lance and accessory before mounting
Clean the connectors of dust and sand
Rinse the detergent bottle and the detergent nozzle
Clean the nozzle
Keep the water inlet fi lter clean and unclogged
Cleaning of the water inlet fi lter
D1 Clean the water inlet fi lter regularly once a month or more frequently according to use.
Carefully loosen the fi lter with a screwdriver and clean it. Check that it is intact before remount-
ing it.
Cleaning of nozzle
A clogging up in the nozzle causes a pump pressure which is too high, why cleaning is re-
quired immediately.
IMPORTANT!
The nozzle cleaning tool (11) should only be used when the nozzle is detached and the ma-
chine is stopped!
D2 Stop the machine and disconnect the nozzle. Clean the nozzle.
D3 Flush the nozzle backwards with water.
I
O
C
D
Loading ...
Loading ...
Loading ...