Depress latch and slide magazine cover open (see
Figure 2).
Figure 2 - Open Magazine
Insert fasteners into magazine. Position fasteners at bottom
of magazine with head towards top of tool (see Figure 3).
NAILING OPERATION
Refer to Figures 5, 6, 7 & 8 (pages 4 and 5).
WARNING: Read and follow all safety rules and operating
instructions in this manual and on warning label of tool before
using this tool. Keep this manual with the tool.
WARNING: Do not use this tool without safety warning
label. If label is missing, damaged or unreadable, contact
Sears to obtain a new label.
WARNING: Never operate tool unless contact trip isin con-
tact with workpiece. Do not operate toolwithoutfasteners or
damage to tool may result.Never fire fasteners intothe air
because fasteners may injure operator or others and damage
to tool may result.
Perform "Safety Mechanism Check" as described in the
Maintenance section (see page 6) prior to first use of tool
and on a daily basis thereafter.
The tool is equipped with a rotating switch that can be set
to rapid-fire or single-fire mode (see Figure 5). When the
switch is set to single-fire mode, the tool will not drive a
second fastener until the trigger is fully released and
pulled again.
When the switch is rotated to rapid-fire mode, the tool can
drive fasteners continuously. A fastener will be fired each
time the contact trip is pressed against the workpiece, as
long as the trigger is maintained in the pulled position.
Figure 3 - Load Magazine
Slide magazine cover forward over magazine until latch
snaps into place, locking magazine cover (see Figure 4).
Figure 5 - Push and rotate switch to select
Operation Mode
Figure 4 - Close Magazine
SINGLE-FIRE OPERATION:
The air tool is equipped with a contact trip safety mecha-
nism that disables tool unless contact trip is pushed
against work. To drive a fastener hold body firmly and
press contact trip on workpiece where fastener is to be
applied. Pull trigger to drive fastener into workpiece. To fire
a second fastener lift the tool from the workpiece, release
the trigger and then repeat the above sequence.
RAPID-FIRE OPERATION:
The tool can also be operated by holding trigger
depressed and pushing contact trip against workpiece. A
fastener will be driven each time the contact trip is pushed
against the workpiece. This operating procedure provides
rapid-fire fastener driving. Never operate tool unless con-
tact trip is in contact with workpiece.