4.4 BURNER & PILOT CLEANING
Periodic cleaning is necessary for proper operation.
Refer to section 4.7, remove the burner, and check that the burner orifice is clean.
Visually inspect the pilot. Brush or blow away any dust, lint, or foreign debris. If the pilot orifice is
plugged, disassembly may be required to remove any foreign material from the orifice or tubing.
When the appliance is back in service, check the pilot flame pattern with the figures in Section 3.3.8.
For re-lighting, refer to the lighting instructions in Section 2.1.
4.5 PILOT ASSEMBLY REPLACEMENT
WARNING
AVERTISSEMENT
THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY
TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO
30 MINUTES BEFORE SERVICING.
LA PROCÉDURE SUIVANTE EST EFFECTUER PAR DU PERSONNEL QUALIFIÉ
COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT
JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
1. Turn off the gas at the meter.
2. Access gas shutoff as per section 3.3.11 on page 33 and turn to off position
3. Remove the door.
4. Remove the logs, bricks and log tray.
5. Remove the burner by loosening the screws and lifting it out.
6. Undo the pilot gas line at the gas valve.
7. Remove the screws fastening the pilot assembly to the pilot bracket and remove the pilot
assembly.
8. Reassemble the components in reverse order.
9. Check all connections thoroughly to ensure there are no gas leaks on reassembly.