20
Standard Power Supply Cord Connectors
Flanged spade connector Ring Connector
Connecting Ground and Neutral Wires
1. Remove center terminal block screw (A) and the ground wire (B)
by removing the external ground connector screw (C).
2. Connect ground (B) and neutral wire (D) to center terminal
block. Tighten screw.
Connecting 4-Wire Connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required where local codes
do not permit the use of 3-wire connections.
Connecting Power Cord Ground Wire
3. Connect ground wire (green or bare) (E) with external ground
connector screw (C). Tighten screw.
Connecting Remaining Wires
4. Connect remaining wires with outer terminal block screws (F).
Tighten screws. Now go to “Dryer Venting Requirements.
ELECTRIC DRYER ELECTRICAL CONNECTIONS
A
C
B
B
D
C
E
F
F
Loading ...
Loading ...
Loading ...