INSTRUCTIONS FOR USE ENGLISH
107408647 - MA10 12E 7
11/2015
SOLUTION FILTER CLEANING
(Figure 10)
1. Remove the tank assembly from the machine body.
2. Remove the two rubber gasket (A and B), then remove the lter strainer (C).
3. Clean and install them on the support (D).
AIR FILTER CLEANING
(Figure 11)
1. Remove the cover (A), then remove the air lter (B).
2. Clean the lter.
3. Install the lter in the housing (C) and close with the cover (A).
TROUBLESHOOTING
Trouble Possible Cause Remedy
The machine does not work. The power supply cable or plug is broken. Replace the cable.
The start/stop switch is broken. Replace the switch. (*)
The dirty water vacuuming is
insufcient.
The recovery tank is full. Empty the tank.
The squeegee bars are dirty or the blades are worn
or damaged.
Clean and check the squeegee bars.
The inspection compartment is dirty. Clean.
The recovery vacuum hose is disconnected or dirty. Connect or clean the hose.
The air lter is dirty. Clean the lter.
The solution ow to the brush is
insufcient.
The solution lter is dirty. Clean the lter.
The solution dispensers are clogged. Clean the solution dispensers.
The squeegees leave marks on the
oor.
There is debris under the squeegee blades. Remove the debris.
The squeegee blades are worn, chipped or torn. Replace the blades.
(*) This maintenance procedure must be performed by an authorised Clarke Service Center.
For further information refer to the Service Manual, available at any Clarke Service Center.
DISPOSAL
Have the machine scrapped by a qualied scrapper.
Before disposal the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Brush
Plastic hoses and components
Electrical and electronic components (*)
(*) Refer to the nearest Clarke Center especially when disposal electrical and electronic components.