Loading ...
Loading ...
Loading ...
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed:
[] level
[] drill with 11/4"(3.0 cm) drill bit
[] pilot hole drill bit (determined by chimney support
attachment method)
[] pencil
[] wire stripper or utility knife
[] measuring tape or ruler
[] pliers
[] caulking gun and weatherproof caulking compound
[] duct tape
[] jig saw or keyhole saw
[] flat blade screwdriver
[] metal snips
[] Phillips screwdriver
Parts needed:
[] 2 UL- or CSA- listed, 1/2"(12.5 mm) strain reliefs
[] power supply cable
[] 1 wall or roof cap
[] metal vent system
[] 4, concrete anchors for 1/4"x 4" hex head lag bolts if
installing into concrete
Parts supplied:
Remove parts from packages. Check that all parts were included.
[] hood canopy assembly with ventilator and light bulbs installed
[] chimney assembly
[] ceiling template
[] Installation Instructions and Use & Care Guide
[] 3 filters
[] hardware package (4 wood shelf bolts, 4 wood shelf bolt
washers, 4 wood shelf nuts, 4 concrete plugs, 1 mounting
template, 1 damper)
Product Dimensions
13_4" 12 V_6"
Recirculating chimney kit dimensions
For recirculating installations, optional Recirculating Chimney Kit
No. 4396911 (Stainless Steel) or Kit No. 4396912 (Meteorite) must
be used. These kits include a new lower chimney cover (that
replaces the lower chimney cover shipped with the island hood),
a charcoal filter and a diverter.
133/4" 12 V_e"
(34.9 cm) (30.6 cm)
IMPORTANT: Observe all governing codes and ordinances.
Island hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or wall.
For recirculating installations see "Recirculating Installations" in
"Install Chimney Covers" section.
All openings in ceiling and where island hood will be installed
must be sealed.
12V2"
(31.8 crn)
5 _
(12.7 crn)
23%"
(60.0crn)
32" (81.3 cm)
rain,
39" (99.1 cm)
rnax.
Loading ...
Loading ...
Loading ...