EMPTYING THE DRAIN TANKS
Climate Pro K36 has drain tanks. During COOL mode, water accumulates in the drain tanks.
When the tanks become full, the self-diagnostic code “FL” is displayed and the unit turns off
automatically.
Note:
If it is necessary to empty the drain tanks before they are full. the unit must be turned o before
emptying. If SCHEDULE MODE operation is running, stop the operation fi rst. (See page 43)
1. Open the drain tank cover.
3. Replace the caps as shown.
5. Empty the tank each.
6. Return the tanks to the unit.
7. Remove the caps and place the condensate float
on the tanks.
8. Close the tank cover so as not to pinch the caps
removed.
9. Press CLEAR bu on to reset the self-diagnostic
code.
10. Press
START
STOP
to restart the operation.
CAUTION
When the tanks are full, remove water immediately.
Do not operate without the tanks. Ensure that the tanks are correctly installed.
Water leaks from the unit may cause property damage or injury due to wet floor.
Cap
2. Remove the condensate float from the
tanks.
4. Remove the two tanks.
Condensate Float