BULB STATUS
NOTE: The “Lamp Operating” LED will glow 3 different colours, indicating different
bulb status.
The variations are as follows:
- Green: Lamp Operating, the lamp is operating as intended
- Yellow: Lamp Life Warning, the lamp is nearing the end of its lifespan,
requires replacement in near future
- Red: Lamp Life exceeded, lamp has reached the end of its lifespan,
requires immediate replacement
When the yellow “Lamp Life Warning” colour is shown, please contact your local
distributor or Air Sniper directly for a replacement. The Induct 300W is designed as a
complete unit, therefore when the bulb expires, the entire unit must be replaced.
The Induct 300W is designed to sanitize in an environment with an airflow of 500
CFM to a maximum of 1500 CFM. If your particular application handles greater
airflow, contact Air Sniper for options that may be better suited to higher airflow
environments.
TROUBLESHOOTING
If your unit is not operating as expected, there are several steps you can take to attempt to
correct the problem.
WARNING: DO NOT attempt to operate the UV-C lamp outside of the duct. UV-C radiation
is extremely harmful to unprotected skin and eyes.
If the Bulb is not operating:
- Inspect the unit and the power cable to verify nothing appears damaged.
- Check that the selected power source is in fact providing power for the unit.
- Check that both ends of the 10’ Power cable are securely connected to either the unit
or the Power source.
- Check that the On/Off switch is flipped to the On position.
- Once airflow is established, the lamp indicator light will be lit.
If the “Lamp Operating (Bulb Life) LED is Red, the bulb has expired. Contact your local
distributor or Air Sniper to replace the unit.