INSTALLATION, USE & CARE INSTRUCTIONS
INSTALLATION
16
WIRING
WARNING
Risk of electric shock. Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards. Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally.
1. Using appropriate wire nuts (not included), connect house
power cable to unit wiring: BLACK to BLACK, WHITE to
WHITE and GREEN or bare wire to GREEN ground screw
(FIG. 30).
2. Reinstall the electrical cover in the unit; ensuring the bottom
tabs are inserted in their embossed location. Secure in
place using its retaining screw (FIG. 31).
CAUTION
Take care not to pinch wires while reinstalling wiring
cover.
INSTALL THE FILTER(S)
Ducted Installation
Reinstall the grease filter(s).
Non-Ducted Installation
PM400SS unit only: Attach the non-ducted filter (included
with the HARKPM21 non-duct kit) to the back of the
grease filter using clips (provided with non-ducted filter).
To order a new non-ducted filter, use service part number
S99010464.
BBN2243SS and BBN2303SS units only: Attach
the non-ducted filters (included with the HARKBN24
or HARKBN30 non-duct kit) to the back of the grease
filters using clips (provided with non-ducted filter). To
order new non-ducted filters, use service part number
S99010464-124 for BBN2243SS and S99010464-130
for BBN2303SS model.
!
WHITE WIRE
BLACK WIRE
HOUSE
POWER
CABLE
FIG. 30
FIG. 31
TABS
GREEN
GROUND
SCREW