INSTALLATION, USE & CARE INSTRUCTIONS
INSTALLATION
15
INSTALL THE UNIT (contd)
horizontal exhauSt inStallation only (contd)
6. Reinstall and secure the faceplate on the unit by securing
the faceplate to the unit using its 4 retaining screws (two
per side, circled in FIG. 28). Plug the blower cable to its
connector on faceplate (FIG. 28).
FIG. 28
FIG. 29
CONNECT DUCTWORK
vertical exhauSt inStallation only
Ducted Installation
Use 6-in. round or 3¼” x 10” metal duct to connect the
adapter damper on the top of the unit to the ductwork
above (FIG. 29). Seal the joint using aluminum duct tape.
Non-Ducted Installation
A non-duct kit is required for this type of installation
(purchase separately). To install, follow the instructions
packed with the kit. Refer to table below to find the
appropriate non-duct kit according to the unit.
Unit model Non-Duct kit model
PM400SS HARKPM21
BBN2243SS HARKBN24
BBN2303SS HARKBN30