5. Remove the hood from its packaging and place the back of the hood on the floor or countertop
in front of the wall where it will hang.
6. Remove the blower shield(s) and blower housing(s) as follows:
a) Remove the shipping tape that is securing the blower shield(s) inside the hood.
b) Remove the blower shield(s) by lightly pulling it toward the front of the hood.
c) Gently close the back draft damper(s) from the top side of the hood.
d) To remove the blower housing(s), unsnap the suitcase latches (one on each side of the
housing).
e) Support the
housing and pull it straight way from the blower housing, then tip it back
toward you to clear the blower wheel(s), and then lower it from the hood.
Make sure power is off at the supply panel / breaker during service or
installation.
7. One blower motor must be removed from each blower assembly to access the connection
box(es). The blower assembly will have a decal identifying the location of the connection
box(es). It is not necessary to remove the blower wheel from the motor.
a) Remove the three screws retaining the blower motor.
b) Pull the motor out far enough so you can reach its electrical connector.
c) Unplug the connector, set the blower motor and screws aside.
8. WIRING PREPARATION: Install an appropriate 1/2” UL listed electrical wire clamp through
each motor box electrical opening on top of the hood. Install electrical wiring from the service
panel to the hood location for each motor box. Consult the connection diagrams (on previous
page) for further details on electrical placement.
See “MODEL NUMBERS” on page4 for power requirements.
Method 1: Extend wiring to 30” above the countertop. Electrical connection(s) will occur
after the hood is installed on the wall.
Method 2: Extend wiring to the hood. Electrical connection(s) will occur before the hood is
installed on the wall.
Electrical (2
)
Connection Diagram (48”- 54” Widths)
Two WM2L Dual Blowers (1200 CFM) (Top View)
Wall side
Centerline
of hood
Motor
Cooling
Vent (4)
8"
[20.3 cm] round
5 1/2"
[14 cm]
1 3/4"
[4.4 cm]
5 1/4"
[13.3 cm]
11"
[29.9 cm]
11"
[29.9 cm]
8"
[20.3 cm] round
INSTALLATION
(CONT.)
©2018 Hestan Commercial Corporation
13