Keystone KSTAD504E 50-pint Dehumidifier For 4500 Sf Rooms Modern Design With 24 Hour Timer And Auto Shut-off

User Manual - Page 3

For KSTAD504E.

PDF File Manual, 8 pages, Read Online | Download pdf file

KSTAD504E photo
Loading ...
Loading ...
Turn off the unit before removing the water bucket.
It may cause the failure of the appliance.
Do not use in areas where chemicals are handled.
This will cause the unit to deteriorate due to chemicals and solvents dissolved in the air.
Do not climb up on or sit on the unit.
You may be injured if you fall or if the unit falls over.
Do not place flower vases or another water container on top of the unit.
Water may spill inside the unit, causing insulation failure and electrical shock or fire.
Electrical Information
The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit.
Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for
protection against shock
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time-delay fuse or circuit
breaker, have a qualified electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not use extension cords or adapter plugs with this unit. However, if it is necessary to use an extension cord, use an approved” Dehumidifier” extension cord only (available
at most local hardware stores).
To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing.
CONTROL PADS ON THE DEHUMIDIFIER
NOTE: The control panel of the unit you purchased may be slightly different according to the models.
Control pads
When you push the button to change operation modes, the unit will make a beep sound to indicate that it is changing modes.
1. Pump Pad
Press to activate the pump operation. NOTE: Make sure the pump drain hose is installed into the unit and the continuous drain hose is removed from the unit before the pump
operation is activated. When the bucket is full, the pump starts to work. Refer to the next pages for removing the collected water. Do not use this operation when the outdoor
temperature is equal to or less than 0°C (32°F).
2. FILTER Pad
The check filter feature is a reminder to clean the Air Filter for more efficient operation. The Filter light(Clean filter I might) will illuminate after 250 hours of operation. To reset after
cleaning the filter, press the Filter pad and the light will go off.
3. COMFORT Pad(optional)
Press to activate the comfort dehumidifying operation. NOTE: On this operation, the unit can not be set humidity level.
4. CONTINUE Pad
Press to activate the continuous dehumidifying operation.
5. TURBO PadControl the fan speed. Press to select either High or Normal fan speed. Set the fan control to High for maximum moisture removal. When the humidity has been
reduced and quiet operation is preferred, set the fan control to Normal.
6. Timer Pad
Press to initiate the Autostart and Auto-stop feature, in conjunction with the ► keypads.
7. /►Up/Down Pads
Humidity Set Control Pads
The humidity level can be set within a range of 35%RH(Relative Humidity) to 85%RH(Relative Humidity) in 5% increments.
For drier air, press the pad and set to a lower percent value(%).
For damper air, press the ► pad and set a higher percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Autostart and Auto stop time from 0.0 to 24.
8. Power Pad Press to turn the dehumidifier on and off.
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time (0-24) while setting, then shows the actual ( ± 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error–Unplug the unit and plug it back in. If the error repeats, call for service.
ES - Tube Temperature sensor of the evaporator error– Unplug the unit and plug it back in. If the error repeats, call for service. P2- Bucket is full or bucket is not in right position–
Empty the bucket and replace it in the right position. (only available for the uint with no pump feature.)
P2- Bucket is full — Empty the bucket.(only available for the unit with pump feature.)
EC- Refrigerant leakage detection– With this new technology, the display area will appear “EC when the unit detects refrigerant leakage, call for service.
E3- Unit malfunction– Unplug the unit and plug it back in. If the error repeats, call for service.
Eb- Bucket is removed or not in right position– Replace the bucket in the right position. (only available for the unit with pump feature.)
Other features
Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in the proper position. When the set humidity is reached, the unit will be shut off
automatically. For some models, the fan motor will continue operating.
Auto Defrost