Winix 1022-0214-00 AM90 PlasmaWave True HEPA Wi-Fi Air Purifier

User Manual - Page 2

For 1022-0214-00. Also, The document are for others Winix models: AM90

PDF File Manual, 12 pages, Read Online | Download pdf file

1022-0214-00 photo
Loading ...
1
4
2
5
3
6
PACKAGE CONTENTS
FRONT BACK
Control Panel
Front Panel
Air Outlet
Vent
Handle
Power Plug
(1) Pre-Filter
(4) Activated Carbon Filters
(1) True HEPA Filter
Unit User Manual
WHERE TO USE
MODEL PART DIAGRAM
12~18 in
12~18 in
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
Electromagnetic interference from certain electronics may cause
product malfunction.
Place indoors away from direct sunlight
Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations.
Allow 12 ~ 18 in. from walls for maximum air flow
01. Fan Speed Indicator
Indicates the current fan speed.
02. Air Quality Indicator
Color coded LED light indicates one of three levels of
Air Quality: Red (poor), Amber (fair), and Blue (good).
03. Wifi Indicator
Indicates when Winix Smart feature is enabled or
disabled.
04. Sleep Mode Indicator
When Sleep Mode is activated, the Air Quality Indicator
LED light is disabled. Fan speed will automatically set
to minimum speed (lower than 'Low') which will be
nearly silent. When Sleep Mode is active, PlasmaWave
®
will be disabled, but it can be turned back on.
CONTROL PANEL
05. Filter Replacement Indicator
LED light indicates when it is time to change the filter.
06. Filter Reset Button
After replacing the filter, turn on the unit and then use
a thin object, such as a paper clip, to press the RESET
button for 5 seconds.
07. PlasmaWave
®
Indicator
Indicates whether PlasmaWave
®
in enabled or disabled.
08. PlasmaWave
®
Button
Enable or disable PlasmaWave
®
.
“When the unit is running, you may hear a chirping
or buzzing sound. The sound is from large particles
passing through PlasmaWave
®
, it is normal and does
not signify product failure.”
Press the PlasmaWave
®
button when the unit is on to
enable or disable this feature.
09. Odor Sensor
Detects the amount of odorous gas in the environment.
When in Auto mode, the fan speed adjusts according
to the detected amount of gas.
10. Power Button
Turns the unit on or off. During the first 30 seconds
of powering up, the Air Quality Indicator will cycle
through Blue, Amber and Red colors.
Odor Sensor takes approximately 4 minutes to
detect the air quality in the environment before
normal operation begins.
11. Fan Speed/Auto/Sleep Buttons
Use the Fan Speed arrow buttons to set the desired
fan speed. Fan Speeds cycle over in this sequence:
Auto, Low, Medium, High, Turbo, Sleep, Auto.
Auto Mode:
Auto Mode automatically adjusts fan speeds
according to your indoor air quality. The fan speed
will adjust to low when air quality is good, medium
when fair, and to high when poor.
Sleep Mode:
When Sleep Mode is activated, the Air Quality Indicator
LED light is disabled.
Fan speed will automatically set to minimum speed
(lower than 'Low') which will be nearly silent.
When Sleep Mode is active, PlasmaWave
®
will be
disabled, but it can be turned back on.
12. Wi-Fi Button
Press for 3 seconds to activate pairing mode.
When Wi-Fi is paired, press the button to turn Wi-Fi
off or back on.
13. Light Sensor
Detects the amount of ambient light within
the environment, to adjust the brightness of
the LED indicators.
When in Auto Mode, the Light Sensor detects when to
put the unit into Sleep Mode.
When to Replace Filters
Filter Indicator Light When to Service When to Replace
Pre-Filter
none Clean once every 14 days Permanent
Activated Carbon Filter
none
Can NOT be WASHED
Replace every 3 months
True HEPA Filter
Lasts Approx. 12 months
When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter.
Intervals between filter replacement may vary depending on environment.
MAINTENANCE
3
True HEPA Filter
2
Activated Carbon Filter
4
PlasmaWave
®
Pre-Filter
1
4-STAGE AIR PURIFICATION
01. Pre-Filter
Designed to catch larger airborne particles found
indoors.
03. True HEPA Filter
Captures 99.97%* of airborne allergens including; pollen,
mold spores, dust, pet dander, microbes, and smoke
(*particles as small as 0.3 microns in size).
02. Activated Carbon Filter
Reduces VOCs and household odors from cooking,
pets, and smoke.
04. PlasmaWave
®
PlamaWave
®
creates Hydroxyls which can help to
reduce the presence of airborne Bacteria, Viruses*
(* Based on laboratory test conducted on Influenza
A Virus H3N2, E. coli, Pseudomonas aeruginosa,
Staphylococcus aureus, Salmonella typhimurium).
INITIAL OPERATION
Latch
1.
Remove the front panel by grasping its upper
edge and gently pulling forward.
2.
Remove the Pre-Filter, then the bag of filters
behind it.
3.
Remove filters from protective plastic wrap.
4.
Install the filters until they fit securely in place.
03. True HEPA Filter (back)
02. Activated Carbon Filter (middle)
01. Pre-Filter (front)
Latch
5.
After filters are installed, close the front panel.
6.
Insert the power cord into an electrical outlet.
After replacing a filter,
press the Filter Reset
button for at least
5 seconds.
REPLACING FILTERS
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean
the Pre-Filter.
If it is excessively soiled, rinse in room temperature
water.
Do not use detergent or soap.
Allow the filter to dry for 24 hours or more before using.
Intervals between filter cleaning may vary
depending on the air quality.
Do not use hot water
over 104
o
F or volatile fluids such as paint thinner.
NOTICE
Do not use benzene, alcohol, or other volatile fluids,
which may cause damage or discoloration.
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room temperature
water.
Afterwards, wipe it down with a clean, dry cloth.
Open the front panel and clean the interior with a
vacuum cleaner.
For optimal performance, clean every 1-2 months.
NOTICE
When cleaning the unit, always unplug the power cord
first and then wait until the unit has cooled down.
Never disassemble, repair, or modify this unit yourself.
Do not use flammable sprays or liquid detergents.
Do not allow children to clean or maintain the unit.
Before cleaning or maintaining, ensure unit is unplugged.
Loading ...
Loading ...
Loading ...