2. Adjust the turndown setting on the valve
• If tted, remove the knobs from the valves.
• Remove rubber grommets from control panel holes.
• Adjust the turndown screw fully clockwise on each
of the 4 valves using a small flat blade screwdriver.
The valve is now set correctly for LPG operation (see
diagram).
3. Connect the test point adaptor to the barbecue gas inlet
• Fit the test point adaptor ensuring the blue sealing
washer is in place and the arrow is pointing in the
direction of gas flow. Do not over-tighten.
4. Connect the hose to the test point adaptor
• Apply thread tape or sealant to the male thread on
the hose and screw into the test point adaptor.
5. Replace the ‘gas type’ sticker
• Locate the ‘Natural Gas’ sticker located on the
barbecue gas inlet and remove it. Put the Universal
LPG sticker in its place.
4 universal LPG installation electrolux integrated barbecue
Preparing the unit for Universal LPG installation.
This barbecue is supplied set up for Natural Gas and is
labelled accordingly. A Universal LPG conversion Kit is
included to enable conversion to Universal LPG.
NOTE
Conversion of this unit to Universal LPG must be carried
out by a qualified licensed person and a Certificate of
Compliance must be issued to the owner on completion of
the installation and conversion.
The required components for conversion have been
supplied. The components are:
• Hose and regulator assembly
• Small plastic bag containing 4 brass injectors
• 1 Universal LPG sticker
• 1 test point adaptor
• 1 sealing washer
1. Change the injectors
• Remove the front cover.
• Release the burner retainer clip as shown.
• Unscrew and replace the 4 injector nipples located
in the end of each tube feeding the burners. The
Universal LPG injectors have a 0.95mm diameter
orifice in them. They appear substantially smaller
than the Natural Gas injectors.
• Re-fasten the clip to retain the tube in the burner.
Do not over tighten or distort supply tube.
• Fit the front cover back on and fasten screws.
Universal LPG installation
LPG injector
turndown screw
test point adaptor –
ensure arrow is pointing
in the right direction
hose with tapered thread
– thread tape required
sealing washer
barbecue gas inlet
remove spring clip
by rotating over
burner tube end
front cover