wolfappliance.com | 5
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations on
pages 6–7. A separate circuit servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)
Specifications
Installation Requirements
The Coee System can be installed in a standard or flush
inset application. The sides of the cabinet opening must
be adequate to support installation of the mounting slides.
Refer to the illustration below.
If a Coee System is installed above a Cup Warming
Drawer, specify one opening for both units.
Finish the edges of the opening.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum ⁄"
(3) reveal is
required on all sides. Each corner of the opening must be
exactly 90° to maintain consistent reveals.
INSTALLATION REQUIREMENTS
Minimum Base Support 100 lb (45 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top ⁄" (5) ⁄" (5)
Bottom 0" (0) 0" (0)
Sides ⁄" (18) 3⁄" (98)
14"
(356)
3"
(
76
)
3
/4" (19)
TYPICAL
Slide support
RATING PLATE
Rating plate location