TO CLEAN AGITATOR:
NOTE: in order to keep cleaning efficiency
high and to prevent damage to your vacuum
cleaner, the aqitator must be cleaned every
time the belt is chan eqed.
The agitator must also be cleaned accord-
ing to the following schedule:
Vacuum Cleaner Use _itator
HEAVY - every week
(used daily)
MODERATE - every month
(used 2-3 times/week)
LIGHT - every 2 months
(used ] time/week)
iMPORTANT
Turn off and unplug vacuum cleaner from
electrical outlet. Check and remove hair,
string and lint build-up frequently in the
PowerMate agitator and end cap areas.
Remove any dirt or debris in the belt path
area or in the brush roller area.
Carefully remove any string or debris lo-
cated on the agitator or end caps.
AGITATOR ASSEMBLY
IEnd CaP Beff Pafh_
LIGHT BULB CHANGING
WARNING
Electrical Shock Or Personal Injury
Hazard
Turn off and unplug vacuum cleaner
before performing maintenance to the
vacuum cleaner. Failure to do so could
result in electrical shock or personal
injury from the vacuum cleaner
suddenly starting.
i cAoT,o.
_Do not plug in or turn on until the vacuum
cleaner is completely reassembled.
1. Remove PowerMate cover as shown in
BELT CHANGNNG AND AGITATOR
CLEANING (pages 21-22).
i
_Pull out to I 2. Remove the light
left side k bulb by pulling
_ straight out.
,
_]lb CAUTION
Do not use a bulb rated over 9W (13V).
During extended use, heat from the bulb
Push in
to right
3. To replace the
light bulb,
carefully insert
fully into slot.
4. Reinstall PowerMate cover as shown in
BELT CHANGING AND AGITATOR
CLEANING (page 21-22).
NOTE: See PARTS AND FEATURES (page 5)
for Bulb number.
- 22 -