31-2000816 Rev. 0 11
Installation
5
GAS SUPPLY
WARNING
Fire Hazard: Do not use a flame to
check for gas leaks.
WARNING
ExplosionHazard:Donotexceed
25ft-lbsoftorquewhenmakinggaslineconnections.
Overtightening may damage the pressure regulator
resultinginfireorexplosionhazard.
Gas Pressure Regulator
Youmustusethegaspressureregulatorsupplied
withthisrangetop.Forproperoperationstheinlet
pressuretotheregulatorshouldbeasfollows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximumpressure:13”ofWaterColumn
Propane (LP) Gas:
Minimum pressure: 11” of Water Column
Maximumpressure:13”ofWaterColumn
If you are not sure about the inlet pressure contact
local gas supplier.
Shut off the main gas supply valve before
disconnecting the old rangetop and leave it off
until the new hook-up has been completed. Don’t
forget to relight the pilot on other gas appliances
when you turn the gas back on.
Because hard piping restricts movement of the
rangetop,theuseofaCSAInternational-certified
flexiblemetalapplianceconnectorisrecommended
unlesslocalcodesrequireahard-pipedconnection.
Ifthehardpipingmethodisused,carefullyalign
thepipe;therangetopcannotbemovedafterthe
connection is made.
Topreventgasleaks,putpipethreadsealanton,or
wrappipethreadtapewithTeflon*aroundallmale
(external)pipethreads.
A. Install provided pressure regulator directly to the
gasinletpipeoftherangetop.Refertothearrow
onthebackoftheregulatorforgasflowdirection.
Ensurethefrontoftheregulatorisfacingtowards
thecabinetfront,easilyaccessiblethroughthe
cabinet doors.
B. Installamanualshut-offvalveinthegaslineina
location easily accessible through the cabinet doors.
C. Whenallconnectionshavebeenmade,ensureall
gas controls are in the off position and turn on the
main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in
the system.
*Teflon: Registered trademark of DuPont
5
GAS SUPPLY (cont.)
Whenusingpressuresgreaterthan1/2psigto
pressuretestthegassupplysystemoftheresidence,
disconnecttherangetopandindividualshut-offvalve
from the gas supply piping. When using pressures
of1/2psigorlesstopressuretestthegassupply
system,simplyisolatetherangetopfromthegas
supplysystembyclosingtheindividualshut-offvalve.
Whencheckingforproperoperationoftheregulator,
the inlet pressure must be at least 1” greater than the
operating (manifold) pressure as given on rating label
of product.
CONNECTOR HOOKUP
TYPICALINSTALLATIONWITHNO
OBSTRUCTION BELOW RANGETOP
A
B
C
D
F
G
E
A. 3/4”NPTmalepipe
thread
B. Regulatorprovidedwith
unit:
• Outlet-3/4”NPT
female pipe thread
• Inlet-1/2”NPTfemale
pipe thread
C. Adapter
D. Flexibleconnector
E. Adapter
F. Manualshut-offvalve
G. Gaspipe1/2”or3/4”
A. 3/4”NPTmalepipethread
B. Elbow
C. Adapter
D. Flexibleconnector(allows
passagethroughcabinetwall)
E. Adapter
F. Regulatorprovidedwithunit:
• Outlet-3/4”NPTfemale
pipe thread
• Inlet-1/2”NPTfemalepipe
thread
G. Gas pipe
H. Manualshut-offvalve
I. Gaspipe1/2”or3/4”
ALTERNATE INSTALLATION WITH
OBSTRUCTION BELOW RANGETOP
A
B
C
D
F
G
E
I
H
Loading ...