6
Gas Connection Basics
Only use the type of gas indicated on the rating plate.
DO NOT connect an unregulated gas line to your grill.
A manual gas shut-off valve must be installed in an easily accessible location between the
supply line and the pressure regulator; both are to be supplied by the installer.
Both your grill and its shut-off valve must be disconnected from the supply line during any
system pressure testing where test pressures may exceed 1/2 Psi (3.5kPa).
Your grill must be isolated from the gas supply line, by closing its manual shut-off valve,
during any pressure testing where test pressures may be equal to or less than 1/2 Psi
(3.5kPa).
The supply line for your grill must be sized and installed to provide sufficient supply of gas to
meet the maximum demand of your grill without undue loss of pressure.
The sealant used on any threaded joints in the supply line must be a type resistant to the
action of LP gases.
Grill Specifications
Grill Input Rating 15,000 BTU/ea
Rotisserie Input Rating 12,500 BTU/ea
Side Burner Input Rating 12,000 BTU/ea
Light Wattage 12V, 20 Watt