Loading ...
Loading ...
Loading ...
Identifying Parts
WARNING
Do not store or use gasoline or other ammable vapours and liquids in the vicinity of this or any other
appliance.
• Avoid re hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any
prong from the power cord.
ELECTRICAL INFORMATION
WARNING
Be sure the electrical supply is adequate for the model you have chosen. This information can be found
on the serial plate, which is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and re hazards, proper grounding
is important. The power cord is equipped with a three-prong grounding plug for protection against
shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you
intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a
quali ed electrician install the proper receptacle.
Ensure the receptacle remains accessible after the unit is installed.
4
TABLE 2
Receptacle and Fuse Types
Rated Volts 125
Amps 15
Wall Outlet
Fuse Size 15
Time Delay Fuse Plug Type
(or Circuit Breaker)
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps
5.9
*AWG Wire Size
14
AWG- American Wire Gauge
*Based on copper wire at 105°C temperature rating
1. All wiring must comply with local and national electrical codes and must be installed by a quali ed electrician. If you
have any questions regarding the following instructions, contact a quali ed electrician.
2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. This 115V air conditioner uses 5.9 or less nameplate amps and may be used in any properly wired, general-purpose
household receptacle. See Table 1 for the speci cations for the individual branch circuit.
4. For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall
outlet. If you are not sure whether your wall outlet is properly grounded, please consult a quali ed electrician.
5. The wall outlet must match the 3-prong plug on the service cord supplied with the unit. DO NOT use plug adapters.
See Table 2 for receptacle and fuse information.