Loading ...
Loading ...
Loading ...
18
English
Troubleshooting
Before calling for service, review this list. It may save you both time and expense. This list includes common experiences that
are not the result of defective workmanship or material in your appliance.
Problem Possible Causes / Solution
Surface burners do not
light
Surface Control Knob has not been completely turned to
position. Push in and turn the Surface Control knob to position
until burner ignites and then turn control to desired flame size.
Ensure gas supply valve is open.
Burner ports or slots are clogged. With the burner off, use a small-gauge wire or needle to clean ports or slots.
Low gas supply level in cylinder.
Surface burner flame
burns half way around
Moisture is present on the burner, dry burner thoroughly.
Burner ports or slots are clogged. With the burner off, clean ports with a small-gauge wire or needle to clean ports or slots.
Moisture is present after cleaning. Lightly fan the flame and allow burner to operate until flame is full. Dry the burners thoroughly.
Surface burner flame
is orange
Dust particles in main line. Allow the burner to operate a few minutes until flame turns blue.
In coastal areas, a slightly orange flame is unavoidable due to salt air.
Control LED only stays
BLUE
The igniter knob control will not change color (Far Left control knob). All other knobs will change to RED when the control is
turned on;
Control knob stays
RED at OFF position
Knob LED PCB Hall components fail to sense the magnet. Contact Furrion for service.
Specification
Technical Specifications
Optional Power
Gas power
BTU/HR
Left and Right Burner: 6500 BTU
Front Burner: 8000 BTU
Oven: 7100 BTU
Fuel / Power
Propane
Inlet Pressure
10” WC Min to 13.8” WC Max
Power Input
12V DC < 2 Amp
Inner Volume of
the Oven
17” Range Oven: 35L
21” Range Oven: 51L
This appliance conforms with the directives: ANSI Z21.57a-(2012) Rec / CAN1-1.16-M79 (R2011)