Control Operation - Service 3
u-line.com
SAFETY INSTALLATI ON & INTEGRATI ON OPERATI NG INSTRUCTIONS MAINTENANCE SERV I CE
SERVI CE M OD E GUI DE
1. THERMI STOR 1 ZON E
This shows the pure thermistor reading with no
offsets taken into account.
2. THERMI STOR 2 EVAPORATOR
This shows the pure thermistor reading with no
offsets taken into account.
3. Does not apply to this model.
4. Does not apply to this model.
5. THERMI STOR 1 ZON E OFFSET
(DO NOT MAKE AN ADJUSTMENT TO THIS WI THOUT
CONTACTING TECH LINE: 800-779-2547)
This calibration is only to be used if actual
temperature at thermistor # 1 is off from set
point.
By adjusting the offset higher we can force the
unit to drive the temperature down below the set
point. (example: adjusting from 0 to + 2 will drop
the unit temperature 2 degrees)
6. THERMI STOR 2 EVAPORATOR OFFSET
(DO NOT MAKE AN ADJUSTMENT TO THIS WI THOUT
CONTACTING TECH LINE: 800-779-2547)
7. THERMI STOR 3 AMBI EN T OFFSET
Not adjustable.
8. Does not apply to this model.
9. THERMI STOR 2 SET POI N T MI N US
OFFSET
This shows the thermistor reading with offsets
taken into account.
10. Does not apply to this model.
11. Does not apply to this model.
12. ADJUST DEFROST I NTERVAL 3 TO 2 4
HOURS
This will adjust the interval between defrosts
from 3 to 24 hours. Adjusting from the factory
settings may cause undesired temperature in
the refrigerator section.
13. ADJUST DEFROST DURATI ON 0 TO 9 9
MI NUTES
The length of the defrost can be adjusted 0 to 99
minutes long. The other defrost parameters still
apply. Lengthening a defrost may cause higher
than normal temperatures in the refrigerator
section.
# Ser vice M ode M enu I te m
1 View thermistor # 1 (no offsets)
2 View thermistor # 2 (no offsets)
3 View thermistor # 3 (no offsets)
4 View thermistor # 4 (no offsets)
5 Adjust thermistor # 1 offset
6 Adjust thermistor # 2 offset
7 Adjust thermistor # 3 offset
8 Adjust thermistor # 4 offset
9 View thermistor # 2 set point no offsets
10 View thermistor # 3 set point no offsets
11 View thermistor # 4 set point no offsets
12 Adjust defrost interval 3 to 24 hours
13 Adjust defrost duration 0 to 99 minutes
14 View error log
15 Clear error log
16 Adjust thermistor # 1 differential
17 Adjust evaporator fan delay in minutes (start of cooling
cycle) 0 - 99 minutes
18 Adjust evaporator fan delay in minutes (after cooling
cycle stops) 0 - 99 minutes
19 Individual component toggle
20 Model number indicator
21 Light all LED segments of display
22 View defrost cycles
23 View compressor run time
24 Activate defrost/ harvest
25 Restore factory defaults
26 View software version - main board
27 View software version - user interface
28 Login period
29 Factory test mode
0Exit service mode
N AVI GATE SERVI CE MODE
Use up or down arrows to scroll through the menu.
Use the light bulb key to enter or exit menu. I f values
have been changed, they will be saved when exiting.
SERV I CE M OD E GUI DE