EN
16
Installation
www.bora.com
5 +0,5
12
10 – 40
Fig. 5.4 Groove dimensions cut-out
Cut-out dimensions when installing cooktops or cooktops
and the BORA cooktop extractor next to each other:
Cooktops/cooktop extractor A in mm B in mm
1/0 344 320
2/0 685 661
3/0 1026 1002
2/1 776 752
3/2 1208 1184
4/2 1549 1525
Tab. 5.2 Cut-out dimensions
INFO If the induction glass ceramic wok is used, the
groove dimensions must be increased to 7 mm
for flush installation.
Surface mounting
x
B ±2
R5
≥ 50
495 ±2
600
≥ 50
Fig. 5.5 Surface mounting
INFO The performance of the cooktop is impaired or
the cooktop overheats if the warm air below
the cooktop cannot escape.
INFO If the cooktop overheats, performance
is reduced or the cooktop switches off
completely (see Overheating protection).
INFO For sufficient air intake, an opening cross-
section in the kitchen units of at least 50 cm
2
is recommended.
Ensure there is sufficient ventilation underneath the
cooktop.
INFO The cable protection (false floor) must not
prevent sufficient ventilation.
> 20
50
Fig. 5.2 Side view of the cable protection and ventilation
5.4 Cut-out dimensions
INFO All dimensions from the front edge of the
front cover.
Please note the worktop overhang x when creating
the worktop cut-out. Applies to flush installation and
surface mounting.
Flush installation
x
≥ 50
A ±2
B ±2
519 ±2
R5
R5
≥ 50
495 ±2
≥ 600
Fig. 5.3 Flush installation