ELECTRICAL PREPARATION
,_ WARNmNG: ELECTRICAL SHOCK
HAZARD - Working on an energized
circuit could result in serious injury or
death. Only qualified electricians should
perform electrical work. Do not attempt
any work on the dishwasher electric
supply circuit until you are certain the
circuit is de-energized.
WARNmNG: FIRE HAZARD - ram-
proper electrical work can cause fire.
Only qualified electricians should per-
form e_ectrica[ work.
Electrical Supply
The customer has the responsibility of ensuring that the
dishwasher electrical installation is in compliance with
all national and local electrical codes and ordinances.
The dishwasher is designed for an electrical supply of
120V, 60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. If the dishwasher is connected with a
food disposer, a 20 amp (and no higher) fuse or circuit
breaker may be used. Electrical supply conductors shall
be a minimum #14 AWG copper wire.
Regardless of where the electrical supply cable enters
the enclosure (following the guidelines on page 9),
position the cable 21" (533mm) from the enclosure's left
side, as shown in Figure 5, letter A so that it will line up
properly with its channel in the dishwasher base when
the dishwasher is placed in its enclosure. Extend the
cable 30" (762mm) from the enclosure's back, as shown
in Figure 5, letter B.
Remove 3" - 4" (75mm - 100mm) of the cable's outer
casing, as shown in Figure 6, letter C, then remove 3/8"
- 1/2" (9 - 13mm) of insulation from each conductor, as
shown in Figure 6, letter D.
Dishwasher Electrical Rating
Ve[ts He_z Amperes Watts
120 60 15 1,450
(max)
f ",
1
[} 30"
(762mm)
L 21"
(533mm)
Figure 5
_., J
C
u_=== 3" = 4" _[
(75ram = 100ram)
D
3/8" = 1/2"
( 8ram- 13ram)
Figure 6
Electrical Preparation 5