6. Aim lamp heads. Each lamphead can be positioned in multiple
directions via the adjustment knob (9) and the lock nut (8).
Note: Make sure to secure all lock nuts and adjustment knobs
tightly (do not overtighten) after nal adjustments are made to
avoid water entry.
CAUTION - Risk of Shock: Aim lamp heads at least
20° down below horizontal in order to prevent water from
accumulating inside lens.
7. Turn on electricity at fuse or circuit breaker box and verify
success of installation.
Note: test xture at night or block photocell. See Trouble shooing
guide for more info.
8. Apply silicone caulking (not included) around the
perimeter of the xture back where it contacts the mounting
surface for moisture seal!
1. Remove xture components and parts pack. Check to
ensure all parts are included. Note: Account for small parts and
destroy packing material, as these may be hazardous to children.
Note: Suitable for wall mount or eave mount. Not suitable for
ground mount installation. Not suitable for use with dimmers,
motion sensors or other remote devices.
Turn OFF Power at circuit breaker box.
CAUTION: Do not rely on wall switch alone to turn o󰀨 power
For installation to properly installed and grounded UL listed
junction box
2. Install cross bar (4) to your junction box using two 3/4” #6 or #8
or #10 screws (5) (screw size is depending on your junction box).
See Fig. A.
CAUTION: WIRING AND FIXTURE OPERATION
Make sure power is turned o. Connect to 120V, 60Hz circuit only.
3. To Ground xture use wire nut (6) to connect the (copper)
house supply ground wire & the green xture ground wire. Note:
If house wiring does not include a ground wire, consult your local
electrical code for approved grounding methods.
For proper connection, place wire nut over wires
and twist clockwise until tight.
4. To Connect supply wires use wire nut (6) to connect the black
xture wire to the black power supply wire and the white xture
wire to the white (neutral) supply wire.
5. To Install xture insert mounting screw (3) into center hole of
xture housing. Align xture over j-box and secure to cross bar by
tightening mounting screw. Note: make sure no wires are pinched
before tightening. Cover center hole in xture housing with rubber
plug (7). See Fig A.
FIXTURE PACKING LIST
Description Quantity
1) LED Light Fixture................................................................. 1
2) Photocontrol ........................................................................ 1
3) 1-1/4”Mounting Screw ........................................................ 1
4) Cross Bar ............................................................................ 1
5) 3/4” #8 & #6 & #10 screws* ................................................. 6
6) Wire Nuts* ........................................................................... 3
7) Rubber Plug* ....................................................................... 1
8) Lock Nut .............................................................................. 2
9) Adjustment Knob ................................................................. 2
*Contained in parts packs
Mounting Hardware Included
Silicone Sealant Required
REQUIRED TOOLS:
Figure A
1) LED Light Fixture
3) Mounting Screw
7) Rubber Plug
4) Cross Bar
5) 3/4” Screws
9) Adjustment Knob
2) Photocontrol
6) Wire Nuts
8) Lock Nut
Loading ...
Loading ...
Loading ...