Installation
56
3. Reposition support "B" so that nozzle "C"
is covered completely.
4. Move the Venturi tube "D" to adjust the
air flow until distance "X" is reached as
indicated in the paragraph (see Table
"Burner and nozzle characteristics" -
"Primary air adjustment (mm)") and then
secure the tube by means of screw "A".
5. After adjusting each burner, reassemble
the appliance correctly.
Adjusting the minimum setting for natural
or town gas
Light the burner and turn it to the minimum
position. Remove the gas tap knob and turn
the adjustment screw next to the tap rod
(depending on the model) until the correct
minimum flame is obtained.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: The
flame should not go out. Repeat the
operation on all gas cocks.
The nozzle tightening torque must
be no more than 3 Nm.