Sirius EASYWALL-200 Wall Flue Kit Extension

Installation.Guide - Page 2

For EASYWALL-200.

PDF File Manual, 2 pages, Read Online | Download pdf file

EASYWALL-200 photo
Loading ...
After checking that there is a clear path to run the ducting, check measure the distance from the Vent position in the external wall, back to
where the ducting will connect to the rangehood collar.
It is best to use as much of the duct as possible to retain rigidity. However in tight installation spaces (short distances) if the length of duct
supplied is too long (compressed length is approx. 1 metre), carefully trim around the circumference of the duct with a
very sharp (Stanley
type) knife to reduce the overall length to suit.
In the pre-determined position on the external wall for it to be installed… using a pencil, neatly mark out around the external wall vents rear
duct collar remembering to allow for the thickness of the duct that will be clamped over the end. Ideally keep the vent position away from
windows, so that the heat, steam and cooking odours being ducted outside, won’t easily re-enter the home.
Use a 12mm drill/spade bit to drill a hole inside the cut-out line for a starting point, then using a jigsaw with an appropriate blade for the walls
material, carefully cut out the required hole to fit the vent. A hole saw if available in the correct size, can also be used instead at this point.
Solid block or masonry walls may need a series of holes drilled with an appropriate masonry bit and then the inner section knocked out with a
hammer and cold c
hisel. If in any doubt whatsoever, please consult a suitably qualified tradesperson if not already using one to install the kit.
After cutting out the hole for the vent, gently feed the ducting from the interior of the home out through the hole and fit over the vent collar and
secure with one of the quick release universal ring clamps provided, being careful not to over tighten.
Feed it all back into the hole and secure the vent either with the screws provided or some other appropriate medium, ensuring that the gasket
is neatly fitted around the edge of the vent to provide a clean and weather resistant seal.
Then carefully feeding/pulling back through from the inside, bring the lower end of the semi-rigid duct down to the connecting collar on the
top of the rangehood. Fit the duct over the rangehood collar and using the other stainless steel universal ring clamp, secure the duct to it.
Agai
n ensuring not to over tighten so as not to tear through the duct.
Arisit Australia Pty. Ltd. 40-44 Mark Anthony Drive, Dandenong South, VIC 3175.
For further advice please call our ducting consultation service on
Ph: 1300 762 219 (Australia only) or visit www.siriusbrand.com
and fill in the fields and one of our trained consultants will only
be too happy to help and assist you in the best manner possible.