Page 16 of 24 801599 - HydroTap BC, BCHA, AIO, User Guide - July 2015 - V2.00
G Settings
3. LCD Screen operation - Section G g Instructions
1. Press [MENU] button for main
menu.
2. Press [Setting] button.
3. Press [Date/Time] button.
4. Select 12 hour mode or 24 hour
mode. The selected mode will be
displayed in dark grey colour with a
tick box on the right.
5. Press [NEXT] button to set time.
G4 HydroTap Set
Date/Time Screen
Set Date / Time
Zip HydroTaps are designed to operate within 1ºC to 2ºC of set point for
boiling water and between 5ºC to 9ºC for chilled drinking water. All boiling
water units are self calibrating to 98ºC, which is the recommended setting.
Adjustments to the 98ºC setting are not recommended however, under
certain circumstances adjustments may be made between 68º - 100ºC. It
should be noted that a 6% energy saving in standby power can be achieved
when the 98ºC setting is selected over the 100ºC setting. Furthermore, the
100ºC setting is not recommended as the delivery rate of water may be
affected.
Set Temperature
If, in section E, you have set a password, then you will need to enter your
password to access the settings screens. If you have forgotten the password,
please disconnect the power and restart your HydroTap unit.
1.
Select individually the hour, minutes
and day and adjust using the up and
down arrows.
2.
Select individually the date, month
and year and adjust using the up and
down arrows.
3.
Press [HOME] to return to the Home
screen.
1. Press the [MENU] button for main
menu.
2. Press the [Settings] button.
3. Press [Enable Password].
4. Then enter your 4-digit password.
You will need to enter your
password to access the settings
screens. If you have forgotten the
password, please disconnect the
power and restart your HydroTap
unit.