Installation
33
EN
A test point (for checking the gas pressure)
is supplied as a separate fitting in the case
of ULPG (propane) appliances.
Connection of the appliance to the gas
supply must be in accordance with the
requirements of AS5601. A ½” BSP
connector at the inlet is recommended and
the gas supply line to the appliance must be
of adequate length to allow sufficient
withdrawal of appliance for service or
disconnection and be:
1. annealed copper pipe or;
2. flexible hose according to AS/NZ1869
& be at least Class “B”, 10 mm diameter.
The appliance must be installed according
to applicable provisions to allow the gas to
be turned off and disconnected for
servicing and removal of the appliance as
required from the gas supply company.
Before the appliance is operated make
certain all relevant parts are placed in the
correct position.
On completion of the installation, the
installer MUST check for gas leaks and test
each burner individually for the correct
flame. Once all burners have been tested
individually, turn all burners on together.
Warranty service calls do not cover these