EXHAUST INFORMATION (continued)
FOR LEFT SIDE EXHAUST
• Never use flexible duct inside dryer
• Straighten up the tab inside the exhaust duct at the back of
appliance (see figure on pg. 4), then remove the internaI duct
connected to the blower housing.
• Cut as shown to remove 8Wls' from the duct and reconnect it to
the blower housing. Make sure that the tab opening is at the
bottom of the duct.
• To secure the duct, insert the tab (located on the appliance
base) in the opening and bend it
• Detach and remove the knockout on the left side panel.
• Use a standard and adjustable metal elbow and a metal straight
duct to exhaust the dryer through the knockout.
• Use only 4" diameter rigid metallic duct 43/4_ i_
• Cover the opening at the back with the plate provided installed
on the back of the appliance L
PARTS AVAILABLE FROM LOCAL SERVICE ORGANIZATION
• Rigid Metal Duct Components
WX8X63 4" x 1 Duct
WX8X64 4" x 2 Duct
WX8X51 4 Eibow
WX8X59 4" Aluminum hood
• Flexible Metal Duct Components
Kit WX8X66 7 Aluminum duct
4" aluminum hood and two clamps
WX8X65 7 Aluminum flexible duct
WX8X58 4 Clamps (2)
F__ 8 3/1, -=4
I JL
'_ SAVE THIS
_\. '- _PORTION
CUT HERE
BLOWER
_[[ HOUSI NG EXHAUST
///-DUCT
BEND TAB IN
I I <--THIS
p I DIRECT ON
BASE OF/ ZTA B
DRYER
REAR OF
/DRYER
"\-- BLOWER HOUSING
_!INSTALL
THE _-'REW- THE PLATE
OPENING SUPPLIED
MINIMUM CLEARANCES
Minimum clearances are - 0 both sides
1 at rear
88" vertical space from floor to ceiling