Installation
19
EN
Warranty service calls do not cover these
adjustments!
To check the operating pressure of the
appliance it is recommended at least 2
large size burners are used. Ensure
appliance is secured to wall when
installation is completed.
N.G. The regulator must be fitted to the ½
BSP thread at the rear of the appliance. An
approved manual shut-off valve must be
installed. The N.G. regulator must be
checked and adjusted to 1.0kPa after
installation.
U.L.P.G. Can be connected to the inlet
fitting directly. The pressure must be
checked to ensure it is operating at
2.75kPa. A separate test point fitting must
be installed between the piping & the
appliance for the pressure to be checked to
ensure it is operating at 2.75kPa.
Connection to LPG
Use a pressure regulator and make the
connection on the gas cylinder following
the guidelines set out in the standards in
force.
The supply pressure must comply with the
values indicated in the table “Burner and
nozzle specifications table”.
Room ventilation
The appliance should be installed in rooms
that have a permanent air supply in
accordance with the standards in force. The
room where the appliance is installed must
have enough air flow for the regular
combustion of gas and the necessary air
change in the room itself. The air vents,
protected by grilles, must be the right size to
comply with current regulations and
positioned so that no part of them is
obstructed, not even partially. The room
must be kept adequately ventilated in order
to eliminate the heat and humidity produced
by cooking: In particular, after prolonged
use, you are recommended to open a
window or to increase the speed of any
fans.
Extraction of the combustion products
The combustion products may be extracted
by means of hoods connected to a natural
draught chimney whose efficiency is certain
or via forced extraction. An efficient
extraction system requires precision
planning by a specialist qualified in this
area and must comply with the positions
and clearances indicated by the applicable
standards.
This domestic appliance is not
connected to a device for
extracting combustion products. It
must be installed and connected in
accordance with current
installation regulations. Pay
particular attention to the relevant
requirements regarding ventilation.