Installation
18
5.5 Gas connection
General information
This appliance is suitable for installation with
Natural Gas or ULPG (propane/butane).
Refer to “Over time the gas cocks may
become difficult to turn and get blocked.
Clean them internally and replace the
lubrication grease.” paragraph for the
relevant burner pressure and appropriate
injector sizes. When the appliance is to be
connected to Natural Gas then the
pressure regulator must be fitted to the gas
inlet.
A test point (for checking the gas pressure)
is supplied either with the regulator or as a
separate fitting in the case of ULPG
(propane) appliances.
Connection of the appliance to the gas
supply must be in accordance with the
requirements of AS5601. A ½” BSP
connector at the inlet is recommended and
the gas supply line to the appliance must be
of adequate length to allow sufficient
withdrawal of appliance for service or
disconnection and be:
1. annealed copper pipe or;
2. flexible hose according to AS/NZ1869
& be at least Class “B”, 10 mm diameter.
The appliance must be installed with
provision to allow the gas to be turned off
and disconnected for servicing and removal
of the appliance as required from the gas
supply. Before the appliance is operated
make certain all relevant parts are placed in
the correct position.
On completion of the installation, the
installer MUST check for gas leaks and test
each burner individually for the correct
flame. Once all burners have been tested
individually, turn all burners on together.
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and
15 Nm.
If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• Installation with flexible hose must be
carried out so that the length of the
piping does not exceed 1,2 metres
when fully extended; make sure that the
hoses do not come into contact with
moving parts and that they are not
crushed in any way.
• The hoses should not come into contact
with moving parts and should not be
crushed in any way.
• The settings for this domestic appliance
are shown on the gas setting label.