LAUNDRY TUB DRAIN SYSTEM
Check location where washer will be
installed. This washer can be installed
using one of three systems:
Laundry tub drain system (below)
Standpipe drain system (p. 13)
Floor drain system (p. 13)
Do not store or operate washer at or
below 32°F (0°C) (some water may
remain in washer), See page 33 for
winterizing information.
Proper installation is your responsibility.
Make sure you have everything neces-
sary for correct installation including the
following points:
Grounded receptacle: Must Hot and cold water faucets:
be within 4 ft (1.2 m) of where Must provide water" pressure
the power cord is attached to between 5-100 psi and be
the back of the washer, within 4 ft (1.2 m) of the hot
and cold water fill valves
J/ attached to the back of the .
Laundry tub dra n system
washer . .
//' " _ Needs a minimum 20 gal
%% (76 L) laundry tub.
2 p must be at
least 39 in (99 cm)
Support: Floor must be sturdy Level floor: Maximum above floor and no
enough to support a total weight allowable slope under entire higher than 96 in
of 315 Ibs (143 kg) (includes washer- 1 in (2.5 cm). (2.4 m) from bottom
washer, water, and load weight), of washer.