Kenmore 79558813900 refrigerator

User Manual - Page 23

For 79558813900.

PDF File Manual, 31 pages, Read Online | Download pdf file

79558813900 photo
Loading ...
Loading ...
Loading ...
BEFORE YOU BEGIN
This water line installation is not warranted by the
refrigerator or icemaker manufacturer. Follow these
instructions carefully to minimize the risk of expensive
water damage.
Water hammer (water banging in the pipes) in house
plumbing can cause damage to refrigerator parts and
lead to water leakage or flooding. Call a qualified
plumber to correct water hammer before installing the
water supply line to the refrigerator
To prevent burns and product damage, do not hook up
the water line to the hot water line.
If you use your refrigerator before connecting the water
line, make sure the icemaker power switch is in the O
(off) position.
Do not install the icemaker tubing in areas where
temperatures fall below freezing.
When using any electrical device (such as a power
drill) during installation, be sure the device is double-
insulated or grounded in a manner to prevent the hazard
of electric shock, or is battery-powered.
All installations local must be in accordance with
plumbing code requirements.
NOTE: Wear eye protection.
WHAT YOU WILL NEED
Copper Tubing, 1/4" outer
diameter to connect the refrigerator
to the water supply. Be sure both
ends of the tubing are cut square.
To determine how much tubing you need: measure
the distance from the water valve on the back of the
refrigerator to the water supply pipe. Then add 8 feet
(2.4 m). Be sure there is sufficient extra tubing (about 8
feet [2.4 m] coiled into 3 turns of about 10 [25 cm]
diameter) to allow the refrigerator to move out from the
wall after installation.
Be sure that the kit you select allows at least 8 feet
(2.4 m) as described above.
A cold water supply.The water pressure must be
between 20 and 120 p.s.i, on models without a water
filter and between 40 and 120 p.s.i, on models with a
water filter.
Power drill.
.½" or adjustable.
wrench.
, Fiat head-and Phillips=
screwdrivers.
Two 1/4" outer diameter
compression nuts and 2
Ferrules (sleeves) to
connect the copper tubing to
the shutoff valve and the
refrigerator water valve.
If your existing copper water
line has a flared fitting at the
end, you will need an
adapter (available at
plumbing supply stores) to
connect the water line to the refrigerator OR you can
cut off the flared fitting with a tube cutter and then use
a compression fitting.
Shutoff valve to connect to
the cold water line. The
shutoff valve should have a
water inlet with a minimum
inside diameter of 5/32" at
the point of connection to the
COLD WATER LINE. Saddle-type shutoff valves are
included in many water supply kits. Before purchasing,
make sure a saddle-type valve complies with your
local plumbing codes.
INSTALLATION INSTRUCTIONS
Install the shutoff valve on the nearest frequently used
drinking water line.
1. SHUTOFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the pressure on
the line.
2. CHOOSE THE VALVE LOCATION
Choose a location for the valve that
is easily accessible. It is best to connect
into the side of a vertical water pipe.
When it is necessary to connect into a
horizontal water pipe, make the
connection to the top or side, eather
than at the bottom, to avoid drawing
off any sediment from the water pipe.
23