Setting up
Avoid locating the appliance it in direct sunlight or near heat sources such as an oven
or a ra di a tor.
The fl oor should be level and even. You can compensate for an uneven fl oor by ad-
just ing the adjustable feet.
Standard EN 378 specifi es that the room in which you install your appliance must
have a volume of 1 m
3
per 8 g of R 600a refrigerant used in the appliance, so as to
avoid the formation of infl ammable gas/air mixtures in the room where the appliance
is located in the event of a leak in the refrigerant circuit. The quantity of refrigerant
used in your appliance is indicated on the type plate on the inside of the appliance.
The appliance is set to operate within specifi c ambient temperature limits according
to its climate rating. These temperature limits should not be exceeded. The correct
climate rating for your appliance is indicated on the type plate.
SN = +10°C to +32°C
SN - ST = +10°C to +38°C
Electrical requirement
Power supply (AC) and voltage at the operating point must comply with the details on
the type plate. The type plate is located on the top left-hand side on the inside of the
appliance. The socket must be fused with a 10 A fuse or higher, it must be away from
the rear of the appliance and must be easily accessible.
16 17
Operating and control elements
n Lower compartment temperature display
o Upper compartment temperature display
p Lower compartment temperature setting buttons
q Upper compartment temperature setting buttons
r Audible warning on/off button
GB
Changing over door hinges
s Interior light on/off button
t Child-proof lock
u On/off button
v Fan button
Fitting dimensions (mm)
Adjust to recess height using the 4 adjus-
table feet on the underside of the appli-
ance.
Connect the appliance to the mains.
Slide the appliance into the recess.
Secure the appliance in the recess
using 4 x 14 screws.
Installation and fi tting
The ventilation cross-section in the plinth panel must be min. 300 cm².