TROUBLESHOOTING
42
Burner
Orifice Size
Main Burner
Φ 1.8 mm
2. Clear ports of any obstructions.
3. Refill the LP tank.
Low heat, LP
gas.
The propane regulator assembly
incorporates an excess flow device
designed to supply the grill with
sufficient gas flow. Rapid changes in
pressure can trigger the excess flow
device, providing a low flame and low
temperature.
Please follow these instructions:
1. Make sure all burners are “OFF.”
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions
listed on the door liner and Page 25
and 26.
Low heat,
natural gas.
Gas pressure is significantly affected
by gas line and length of gas line from
house gas line.
Check your gas line and make
corrections by following the chart
below:
From House to Grill
Distance
Tubing Size
Up to 25 ft.
3/8 in. DIA
2650 ft.
1/2 in. DIA
51100 ft.
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
Over 101 ft.
3/4 in. DIA
Cooking light
will not turn on.
1. No power supply.
2. Defective Halogen bulb.
3. Internal wiring issue.
1. Check power supply and make
sure it is properly plugged in.
2. Replace the bulb.
3. Check the wiring connections
under the fire box. All wire
connections must be tight. If any
wires are damaged they should be
replaced.
Loading ...