Waeco CF-40 9600008649 CF SERIES Portable Fridge/Freezer 40L

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Installation Instruction

Operating manual

This is the main product document for model 9600008649. Series: CF SERIES
Additionally, the document applies to other Waeco models: CF18, CF25, CF35, CF50

The file format is pdf, 28 pages, you can download this manual here .

background
CF18, CF25, CF35, CF40, CF50
Compressor Cooler
Operating manual
EN
PORTABLE REFRIGERATION
CF SERIES
CF18-CF60-O-AUS.book Seite 1 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50
2
Please read this operating manual carefully before starting the device.
Keep it in a safe place for future reference. If the device is passed on to
another person, this operating manual must be handed over to the user
along with it.
The manufacturer cannot be held liable for damage resulting from improper usage
or incorrect operation.
Contents
1 Explanation of symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6 Function description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
8 Cleaning and maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
9 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
11 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
CF18-CF60-O-AUS.book Seite 2 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Explanation of symbols
3
1 Explanation of symbols
D
!
!
A
I
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences and excess voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
DANGER!
Safety instruction: Failure to observe this instruction will cause fatal or
serious injury.
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
CF18-CF60-O-AUS.book Seite 3 Dienstag, 27. Februar 2018 2:14 14
background
EN
Safety instructions CF18, CF25, CF35, CF40, CF50
4
2.1 General safety
D
DANGER!
When using the device on boats: If the device is powered by the AC
mains, ensure that the power supply is protected with a ground fault
interrupter circuit.
!
WARNING!
Do not operate the device if it is visibly damaged.
If this device's power cable is damaged, it must be replaced by the
manufacturer, customer service or a similarly qualified person in order
to prevent safety hazards.
This device may only be repaired by qualified personnel. Improper
repairs can lead to considerable hazards.
This device can be used by children aged 8 years or over, as well as by
persons with diminished physical, sensory or mental capacities or a
lack of experience and/or knowledge, providing they are supervised
or have been taught how to use the device safely and are aware of the
resulting risks.
Cleaning and user maintenance must not be carried out by children
without supervision.
Children must not play with the device.
Children must be supervised to ensure that they do not play with the
device.
Always keep and use the device out of the reach of children under the
age of 8 years.
Do not store any explosive substances such as spray cans with a
flammable propellant in the device.
!
CAUTION!
Disconnect the device from the power supply
before each cleaning and maintenance
after every use
Food may only be stored in its original packaging or in suitable
containers.
A
NOTICE!
Check that the voltage specification on the type plate corresponds to
that of the energy supply.
CF18-CF60-O-AUS.book Seite 4 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Safety instructions
5
Only connect the device as follows:
With the DC cable to a DC plug socket in the vehicle (e. g.
cigarette lighter)
Or with the AC connection cable to the AC mains supply
Never pull the plug out of the socket by the cable.
If the cooler is connected to the DC socket: Disconnect the cooler and
other power consuming devices from the battery before connecting
the quick charging device.
If the cooler is connected to the DC socket: Disconnect the cooler or
switch it off when you turn off the engine. Otherwise you may dis-
charge the battery.
The cooling device is not suitable for transporting caustic materials or
materials containing solvents.
The cooling device contains inflammable cyclopentane in the
insulation. The gases in the insulation material require special disposal
procedures. Deliver the device at the end of its life-cycle to an appro-
priate recycling.
2.2 Operating the device safely
!
CAUTION!
Before starting the device, ensure that the power supply line and the
plug are dry.
A
NOTICE!
Do not use electrical devices inside the cooler unless they are
recommended by the manufacturer for the purpose.
Do not place the device near naked flames or other heat sources
(heaters, direct sunlight, gas ovens etc.).
Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat that
arises during operation does not build up. Make sure that the device
is sufficiently far away from walls and other objects so that the air can
circulate.
Ensure that the ventilation openings are not covered.
Do not fill the inner container with ice or fluid.
Never immerse the device in water.
Protect the device and the cable against heat and moisture.
CF18-CF60-O-AUS.book Seite 5 Dienstag, 27. Februar 2018 2:14 14
background
EN
Scope of delivery CF18, CF25, CF35, CF40, CF50
6
3Scope of delivery
Item Quantity Description
1 1 Cooler
2 1 Connection cable for DC connection
31
Only CF35, CF40, CF50
Connection cable for AC connection
42
Only CF35, CF40, CF50
Carrying handle, consisting of:
–2 holders
–1 handle
4 fastening screws
–1
Only CF18
Plastic grille divider
–1
Only CF35
Powdercoated steel evaporator protector
–1
Only CF40, CF50
Powdercoated steel basket
–1Operating manual
4
2
3
1
1
CF18-CF60-O-AUS.book Seite 6 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Accessories
7
4Accessories
Available as accessories (not included in the scope of delivery):
If you have questions regarding the accessories, contact your local service partner.
5 Intended use
The cooler is suitable for cooling and freezing foods.
The cooler is designed to be operated from:
a DC on-board power supply of a vehicle, boat or caravan
a DC auxiliary battery
an AC power supply (CF35, CF40, CF50)
For operating CF 18, CF25 at AC mains you need an AC/DC power supply rectifier
(accessory).
!
6 Function description
The cooler can refrigerate or freeze food products. A fast-acting and efficient cooling
system provides low maintenance cooling performance with a compressor and con-
trol module.
The cooler is designed for mobile use and can be carried by using a folding carrying
bracket (CF18), two recessed grips (CF25) or two removable carrying handles
(CF35, CF40, CF50).
The cooler can withstand a short-term inclination of 30°, for example on boats.
Description Ref. no.
For CF18, CF25:
AC/DC power supply rectifier
EPS-817
9109002086
CAUTION! Health hazard!
Please check if the cooling capacity of the device is suitable for storing
the food or medicine you wish to cool.
CF18-CF60-O-AUS.book Seite 7 Dienstag, 27. Februar 2018 2:14 14
background
EN
Function description CF18, CF25, CF35, CF40, CF50
8
6.1 Scope of functions
6.2 Operating and display elements
Latch for lid
CF18 CF25
CF35, CF40,
CF50
Power supply with priority circuit for
connecting to the power supply
Battery monitor to protect the
vehicle battery 2-level 3-level
Turbo mode for rapid cooling
Display with temperature gauge
(switches off automatically at low
battery voltage)

Temperature setting rotary-knob two buttons in steps of 1 °C (2 °F)
Removable carrying handles
1
CF 25, CF 35, CF 40
2
CF18-CF60-O-AUS.book Seite 8 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Function description
9
Operating panel and DC power supply inlet (CF18)
Item Description Explanation
1 TEMPERATURE Temperature controller,
cooling temperature at the end positions:
COLD: +10 °C (+50 °F)
FREEZE: –18 °C (0 °F)
2 POWER Status indication
LED lights up green: Device is switched on and
ready for operation
LED lights up yellow: Set temperature has been
reached
3 ERROR LED flashes red: Device is switched on but not
ready for operation
4 BATTERY MONITOR Switch-on device/battery monitor:
0: Device is switched off
HIGH: Device is switched on, battery
monitor is in HIGH mode
LOW: Device is switched on, battery
monitor is in LOW mode
5
12/24 Vg
DC voltage supply inlet
CF 18
1 2 3 4
5
3
CF18-CF60-O-AUS.book Seite 9 Dienstag, 27. Februar 2018 2:14 14
background
EN
Function description CF18, CF25, CF35, CF40, CF50
10
Operating panel (CF25, CF35, CF40, CF50)
Item Description Explanation
1ON
OFF
Switches the cooler on or off when the button is pressed for
between one and two seconds
2 POWER Status indication
LED lights up green: Compressor is on
LED lights up orange: Compressor is off
LED flashes orange: Display switched off
automatically due to low
battery voltage
3 ERROR LED flashes red: Device is switched on but not
ready for operation
4 SET Selects the input mode
– Temperature setting
– Celsius or Fahrenheit display
– Set battery monitor
5 Display, shows the information
6 UP + Press once to increase the value
7 DOWN – Press once to decrease the value
CF 25, CF 35, CF 40, CF 50
ON
OFF
SET
POWER
UP
+
DOWN
ERROR
°
1 3 4 5 6 72
4
CF18-CF60-O-AUS.book Seite 10 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Function description
11
Connection sockets (CF25, CF35, CF40, CF50)
Item in
fig. 5
Description
1 DC voltage supply inlet
2 Emergency switch
Item in
fig. 6
Description
1 AC voltage supply inlet
2Fuse holder
3 DC voltage supply inlet
4 Emergency switch
1
CF 25
EMERGENCY
OVERRIDE
NORMAL
USE
2
5
100-240V~AC
FUSE
12/24V DC
1
2 3
CF 35, CF 40, CF 50
EMERGENCY
OVERRIDE
NORMAL
USE
4
6
CF18-CF60-O-AUS.book Seite 11 Dienstag, 27. Februar 2018 2:14 14
background
EN
Operation CF18, CF25, CF35, CF40, CF50
12
7Operation
7.1 Before initial use
I
Mounting the handles
The handles are enclosed unassembled. If you wish to attach the handles, proceed
as follows:
Make a handle by putting two holders (1) and a handle (2) together.
Fasten the grip with the enclosed screws in the holes provided.
NOTE
Before starting your new cooler for the first time, you should clean it
inside and outside with a damp cloth for hygienic reasons (please also
refer to the chapter “Cleaning and maintenance” on page 22).
1
2
1
CF 35, CF 40, CF 50
7
CF18-CF60-O-AUS.book Seite 12 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Operation
13
Turning the lid around (CF50)
You can turn the lid around if you want to open the lid from the other side. To do this,
proceed as follows:
Open the lid and pull it out (A).
Turn the lid.
Insert the lid in the lid holders on the opposite side of the cooler (B).
Selecting the temperature units (CF25, CF35, CF40, CF50)
You can switch the temperature display between Celsius and Fahrenheit. This is how
to do it:
Switch on the cooler.
Press the “SET” button (fig. 4 4, page 10) twice.
Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons
to select Celsius or Fahrenheit.
The selected temperature units then appear in the display for a few seconds. The
display flashes several times before it returns to the current temperature.
CF 50
AB
8
CF18-CF60-O-AUS.book Seite 13 Dienstag, 27. Februar 2018 2:14 14
background
EN
Operation CF18, CF25, CF35, CF40, CF50
14
7.2 Energy saving tips
Choose a well ventilated location which is protected from direct sunlight.
Allow warm food to cool down first before placing it in the cooling device.
Do not open the cooling device more often than necessary.
Do not leave the cooling device open for longer than necessary.
Defrost the cooling device once a layer of ice forms.
Avoid unnecessarily low temperatures.
7.3 Connecting the cooler
Connecting to a battery (vehicle or boat)
The cooler can be operated with 12 V
g or 24 Vg.
A
For safety reasons the cooler is equipped with an electronic system to prevent
polarity reversal. This protects the cooler against short-circuiting when connecting to
a battery.
Using the fused DC plug
A
Plug the DC connection cable (fig. 1 2, page 6) into the DC power supply inlet
of the cooler (fig. 5 1, page 11/fig. 6 3, page 11).
Connect the connection cable to a DC power outlet.
NOTICE! Danger of damage!
Disconnect the cooler and other consumer units from the battery before
you connect the battery to a quick charging device.
Overvoltage can damage the electronics of the device.
NOTICE! Danger of damage!
For protection of the device the DC cable supplied includes a fuse inside
the plug. Do not remove the fused DC plug.
Only use the DC cable supplied.
CF18-CF60-O-AUS.book Seite 14 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Operation
15
Connecting to an AC power supply (e.g. in the home or office)
(CF35, CF40, CF50)
D
The coolers have an integrated multi-voltage power supply with priority circuit for
connecting to an AC voltage source. The priority circuit automatically switches the
cooler to power supply operation if the device is connected to an AC power supply,
even if the DC connection cable is still attached.
When switching between the AC power supply and the battery supply, the red LED
may light up briefly.
Plug the AC connection cable (fig. 1 3, page 6) into the AC power supply inlet
of the cooler (fig. 6 1,page 11).
Connect the connection cable to the AC power outlet.
7.4 Using the battery monitor
The device is equipped with a multi-level battery monitor that protects your vehicle
battery against excessive discharging when the device is connected to an on-board
DC supply.
If the cooler is operated when the vehicle ignition is switched off, the cooler switches
off automatically as soon as the supply voltage falls below a set level. The cooler will
switch back on once the battery has been recharged to the restart voltage level.
A
DANGER! Danger of electrocution!
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
If you are operating your cooler on board a boat from a power supply
connection of 100 240 V
w, you must install a residual current
circuit breaker between the 100 240 V AC power supply and the
cooler.
Seek advice from a trained technician.
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no longer be
fully charged. For in-vehicle installations, avoid repeated starting and
shutting off of the engine. Allow the vehicle to recharge the battery
before powering the cooler on.
CF18-CF60-O-AUS.book Seite 15 Dienstag, 27. Februar 2018 2:14 14
background
EN
Operation CF18, CF25, CF35, CF40, CF50
16
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and
“MED” (see the following table).
Selecting the battery monitor mode (CF18)
Slide the selection switch (fig. 3 4, page 9) to select the battery monitor mode.
Selecting the battery monitor mode (CF25, CF35, CF40, CF50)
Switch on the cooler.
Press the “SET” button (fig. 4 4, page 10) three times.
Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons
to select the battery monitor mode.
Display will be as follows:
Lo (LOW), Πed (MED) or HI (HIGH)
The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I
CF18 CF25, CF35, CF40, CF50
Battery monitor mode LOW HIGH LOW MED HIGH
Switch-off voltage at 12 V
10.4 V 11.5 V 10.1 V 11.4 V 11.8 V
Restart voltage at 12 V
11.5 V 12.5 V 11.1 V 12.2 V 12.6 V
Switch-off voltage at 24 V
22.1 V 24.0 V 21.5 V 24.1 V 24.6 V
Restart voltage at 24 V
23.6 V 25.4 V 23.0 V 25.3 V 26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC power supply, set the
battery monitor to the “LOW” position.
CF18-CF60-O-AUS.book Seite 16 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Operation
17
7.5 Using the cooler
A
Place the cooler on a firm foundation.
Make sure that the ventilation slots are not covered and that the heated air can
dissipate.
I
Close the cooler, see chapter “Connecting to a battery (vehicle or boat)” on
page 14.
I
CF18
Set the slide switch (fig. 3 4, page 9) to "HIGH" when power is supplied by
your vehicle's starter battery.
Set the slide switch (fig. 3 4, page 9) to "LOW" when power is supplied by an
external DC power supply source.
The “POWER” LED is lit green.
The cooler starts cooling the interior.
When the cooling temperature has been reached, the “POWER” LED is lit yellow.
NOTICE! Danger of overheating!
Ensure at all times that there is sufficient ventilation so that the heat that
generated during operation can dissipate. Ensure that the ventilation
slots are not covered. The cooler MUST maintain a MINIMUM of 50 mm
away from walls or similar surfaces which could restrict important air flow
requirements of the cooling system.
NOTE
Place the cooler as shown (fig. 1, page 6). If you operate the box in a
different position it can be damaged.
NOTE
If you wish to operate the cooler from the AC power supply, set the
battery monitor to the “LOW” position.
CF18-CF60-O-AUS.book Seite 17 Dienstag, 27. Februar 2018 2:14 14
background
EN
Operation CF18, CF25, CF35, CF40, CF50
18
CF25, CF35, CF40, CF50
Press the “ON/OFF” button (fig. 4 1, page 10) for between one and two
seconds.
The “POWER” LED lights up.
The display (fig. 4 5, page 10) switches on and shows the current temperature.
I
The cooler starts cooling the interior.
I
Latching the cooler lid (CF35, CF40)
Close the lid.
Press the latch (fig. 2 1, page 8) down, until it latches in place audibly.
7.6 Setting the temperature
A
CF18
Set the cooling level with the temperature controller (fig. 3 1, page 9).
CF25, CF35, CF40, CF50
Press the “SET” button (fig. 4 4, page 10) once.
Use the “UP +” (fig. 4 6, page 10) and “DOWN –” (fig. 4 7, page 10) buttons
to select the cooling temperature.
The cooling temperature appears in the display for a few seconds. The display
flashes several times and then the current temperature is displayed again.
NOTE
The temperature displayed is that of the middle of the interior.
The temperatures elsewhere can deviate from this temperature.
NOTE
During low voltage:
If switched off by the battery monitor due to low voltage, the display
goes blank, and the LED “POWER” flashes orange.
NOTICE! Danger from excessively low temperature!
Ensure that the only those objects are placed in the cooler that are
intended to be cooled at the selected temperature.
CF18-CF60-O-AUS.book Seite 18 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Operation
19
7.7 Using the Emergency Switch
The emergency override switch ((fig. 5 2, page 11 and fig. 6 4, page 11) is
located in the connection panel.
For normal operation the switch should be in the NORMAL USE position.
In the unlikely event of an electronic control failure slide the switch to
EMERGENCY OVERRIDE.
I
7.8 Switching off the cooler
Empty the cooler.
Switch the cooler off.
Pull out the connection cable.
If you do not want to use the cooler for a longer period of time:
Leave the lid slightly open. This prevents odor build-up.
7.9 Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the evaporator. This
reduces the cooling capacity. Defrost the device in good time to avoid this.
A
To defrost the cooler, proceed as follows:
Remove the contents.
If necessary, place them in another cooling device to keep them cool.
Switch off the device.
Leave the lid open.
Wipe off the defrosted water.
NOTE
In this position the appliance will run all the time and will therefore per-
form as a freezer only.
NOTICE! Danger of damage!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
CF18-CF60-O-AUS.book Seite 19 Dienstag, 27. Februar 2018 2:14 14
background
EN
Operation CF18, CF25, CF35, CF40, CF50
20
7.10 Replacing the AC fuse (CF35, CF40, CF50)
D
Pull off the connection cable.
Pry out the fuse insert (fig. 6 2, page 11) with a screwdriver.
Replace the defective fuse with a new one that has the same rating (T4AL 250 V).
Press the fuse insert back into the housing.
7.11 Replacing the DC plug fuse
Pull the adapter sleeve (4) off of the plug.
Unscrew the screw (5) out of the upper half of the housing (1).
Carefully raise the upper half of the housing from the lower (6) half.
Take out the contact pin (3).
Replace the defective fuse (2) with a new fuse of the same type and rating (8 A
32 V).
Re-assemble the plug in the reverse order.
DANGER! Danger of electrocution!
Disconnect the connection cable before you replace the device fuse.
1 2 3
4
5
6
9
CF18-CF60-O-AUS.book Seite 20 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Operation
21
7.12 Replacing the light bulb (CF25, CF35, CF40, CF50)
Press the switch pin (2) downwards so that the transparent part (1) of the lamp can
be removed at the front.
Replace the light bulb.
I
Press the transparent part of the lamp back into the housing.
NOTE
The LEDs in the light bulb must facing the transparent part of the lamp.
1 2
0
CF18-CF60-O-AUS.book Seite 21 Dienstag, 27. Februar 2018 2:14 14
background
EN
Cleaning and maintenance CF18, CF25, CF35, CF40, CF50
22
8 Cleaning and maintenance
!
A
Occasionally clean the device interior and exterior with a damp cloth.
Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
9Guarantee
The statutory warranty period applies. If the product is defective, please contact the
manufacturer's branch in your country (see the back of the instruction manual for the
addresses) or your retailer.
For repair and guarantee processing, please include the following documents when
you send in the device:
A copy of the receipt with purchasing date
A reason for the claim or description of the fault
WARNING!
Always disconnect the device from the power supply before you clean
and service it.
NOTICE! Risk of damage
Never clean the cooler under running water or in dish water.
Do not use abrasive cleaning agents or hard objects during cleaning
as these can damage the cooler.
CF18-CF60-O-AUS.book Seite 22 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Troubleshooting
23
10 Troubleshooting
Fault Possible cause Suggested remedy
Device does not
function, LED does
not glow.
No voltage was
detected in the DC
power outlet.
In most vehicles the ignition must be
turned on before power will be supplied
to the DC power outlet.
No voltage present in
the AC voltage outlet.
Try using another plug outlet.
The device fuse is
defective.
Replace the device fuse, see chapter
“Replacing the AC fuse (CF35, CF40,
CF50)” on page 20.
The integrated power
supply adapter is
defective.
This can only be repaired by an
authorized repair center.
The device does not
cool (plug is inserted,
“POWER” LED is lit).
Defective compressor. This can only be repaired by an
authorized repair center.
The device does not
cool (plug is inserted,
“POWER” LED flashes
orange, display is
switched off).
Battery monitor is set
too high.
Select a lower battery monitor setting.
Battery voltage is too
low.
Test the battery and charge it as needed.
When operating from
the DC outlet:
The ignition is on
and the device is not
working and the LED
is not lit.
The DC outlet is dirty.
This results in a poor
electrical contact.
If the plug of your cooler becomes very
warm in the DC outlet, either the DC
outlet must be cleaned or the plug has
not been assembled correctly.
The fuse of the DC plug
has blown.
Replace the fuse in the DC plug, see
chapter “Replacing the DC plug fuse” on
page 20.
The vehicle fuse has
blown.
Replace the vehicles DC outlet fuse.
Please refer to your vehicles operating
manual.
CF18-CF60-O-AUS.book Seite 23 Dienstag, 27. Februar 2018 2:14 14
background
EN
Disposal CF18, CF25, CF35, CF40, CF50
24
11 Disposal
Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
The display shows an
error message (e.g.
“Err1”) and the appli-
ance does not cool.
The appliance has
switched off due to an
internal fault.
This can only be repaired by an
authorized repair center.
The interior light of a
compartment flashes.
The lid of the
compartment has been
left open for more than
three minutes.
Close the lid of the compartment.
Fault Possible cause Suggested remedy
CF18-CF60-O-AUS.book Seite 24 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Technical data
25
12 Technical data
CF18 CF25
Connection voltage: 12/24 Vg
Rated current
– 12 Vg:3.1A6.8A
– 24 Vg:1.9A 3.0A
100–240Vw:–
Cooling capacity: +10 °C to –18 °C (+50 °F to +0.4 °F)
Storage volume: 18 l 23 l
Climate class: N, ST, T
Ambient temperature: 18 °C to 43 °C (+50 °F to 109.4 °F)
Noise emission:
Refrigerant quantity: 38 g 40 g
CO
2
equivalent: 0.054 t 0.057 t
Global warming potential (GWP): 1430
Dimensions (W x H x D) in mm: 465 x 414 x 300 260 x 425 x 550
Weight: 12 kg 12.7 kg
Test/certificates:
CF18-CF60-O-AUS.book Seite 25 Dienstag, 27. Februar 2018 2:14 14
background
EN
Technical data CF18, CF25, CF35, CF40, CF50
26
CF35 CF40
Connection voltage: 12/24 Vg and 100 240 Vw
Rated current
– 12 Vg:6.0 A
– 24 Vg:3.0 A
100–240Vw: 1.3 A to 0.7 A
Cooling capacity: +10 °C to –18 °C (+50 °F to +0.4 °F)
Storage volume: 31 l 37 l
Climate class: N, ST, T
Ambient temperature: 18 °C to 43 °C (+50 °F to 109.4 °F)
Noise emission: 45 dB(A)
Refrigerant quantity: 45 g
CO
2
equivalent: 0.064 t
Global warming potential (GWP): 1430
Dimensions (W x H x D) in mm: 360 x 385 x 580 360 x 445 x 580
Weight: 15.5 kg 17.2 kg
Test/certificates:
CF18-CF60-O-AUS.book Seite 26 Dienstag, 27. Februar 2018 2:14 14
background
EN
CF18, CF25, CF35, CF40, CF50 Technical data
27
I
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
CF50
Connection voltage: 12/24 Vg and 100 240 Vw
Rated current
– 12 Vg:7.0 A
– 24 Vg:3.0 A
100–240Vw: 1.3 A to 0.7 A
Cooling capacity: +10 °C to –18 °C (+50 °F to +0.4 °F)
Storage volume: 47 l
Climate class: N, ST, T
Ambient temperature: 18 °C to 43 °C (+64.4 °F to 109.4 °F)
Noise emission: 45 dB(A)
Refrigerant quantity: 45 g
CO
2
equivalent: 0.064 t
Global warming potential (GWP): 1430
Dimensions (W x H x D) in mm: 630 x 480 x 360
Weight: 18.5 kg
Test/certificates:
NOTE
If the ambient temperature is above 32 °C (90 °F), the minimum
temperature cannot be attained.
CF18-CF60-O-AUS.book Seite 27 Dienstag, 27. Februar 2018 2:14 14
background
AUSTRIA
Dometic Austria GmbH
Neudorferstraße 108
A-2353 Guntramsdorf
+43 2236 908070
+43 2236 90807060
BENELUX
Dometic Branch Office Belgium
Lourdesstraat 84
B-8940 Geluwe
+32 2 3598040
+32 2 3598050
BRAZIL
Dometic DO Brasil LTDA
Avenida Paulista 1754, conj. 111
SP 01310-920 Sao Paulo
+55 11 3251 3352
+55 11 3251 3362
DENMARK
Dometic Denmark A/S
Nordensvej 15, Taulov
DK-7000 Fredericia
+45 75585966
+45 75586307
FINLAND
Dometic Finland OY
Mestarintie 4
FIN-01730 Vantaa
+358 20 7413220
+358 9 7593700
FRANCE
Dometic SAS
ZA du Pré de la Dame Jeanne
B.P. 5
F-60128 Plailly
+33 3 44633525
+33 3 44633518
Mail : vehiculesdeloisirs@dometic.fr
GERMANY
Dometic WAECO International GmbH
Hollefeldstraße 63 · D-48282 Emsdetten
+49 (0) 2572 879-0
+49 (0) 2572 879-300
Mail: info@dometic-waeco.de
HONG KONG
Dometic Group Asia Pacific
Suites 2207-11 · 22/F · Tower 1
The Gateway · 25 Canton Road,
Tsim Sha Tsui · Kowloon
+852 2 4611386
+852 2 4665553
HUNGARY
Dometic Zrt. Sales Office
Kerékgyártó u. 5.
H-1147 Budapest
+36 1 468 4400
+36 1 468 4401
Mail: budapest@dometic.hu
ITALY
Dometic Italy S.r.l.
Via Virgilio, 3
I-47122 Forlì (FC)
+39 0543 754901
+39 0543 754983
Mail: vendite@dometic.it
JAPAN
Dometic KK
Maekawa-Shibaura, Bldg. 2
2-13-9 Shibaura Minato-ku
Tokyo 108-0023
+81 3 5445 3333
+81 3 5445 3339
MEXICO
Dometic Mx, S. de R. L. de C. V.
Circuito Médicos No. 6 Local 1
Colonia Ciudad Satélite
CP 53100 Naucalpan de Juárez
Estado de México
+52 55 5374 4108
+52 55 5393 4683
NETHERLANDS
Dometic Benelux B.V.
Ecustraat 3
NL-4879 NP Etten-Leur
+31 76 5029000
+31 76 5029019
NEW ZEALAND
Dometic New Zealand Ltd.
PO Box 12011
Penrose
Auckland 1642
+64 9 622 1490
+64 9 622 1573
NORWAY
Dometic Norway AS
Østerøyveien 46
N-3232 Sandefjord
+47 33428450
+47 33428459
Mail: firmapo[email protected]
POLAND
Dometic Poland Sp. z o.o.
Ul. Puławska 435A
PL-02-801 Warszawa
+48 22 414 3200
+48 22 414 3201
PORTUGAL
Dometic Spain, S.L.
Branch Office em Portugal
Rot. de São Gonçalo nº 1 – Esc. 12
2775-399 Carcavelos
+351 219 244 173
+351 219 243 206
RUSSIA
Dometic RUS LLC
Komsomolskaya square 6-1
RU-107140 Moscow
+7 495 780 79 39
+7 495 916 56 53
SINGAPORE
Dometic Pte Ltd
18 Boon Lay Way
06–141 Trade Hub 21
Singapore 609966
+65 6795 3177
+65 6862 6620
SLOVAKIA
Dometic Slovakia s.r.o.
Sales Office Bratislava
Nádražná 34/A
900 28 Ivánka pri Dunaji
/ +421 2 45 529 680
Mail: bratislava@dometic.com
SOUTH AFRICA
Dometic (Pty) Ltd.
Regional Office
South Africa & Sub-Saharan Africa
2 Avalon Road
West Lake View Ext 11
Modderfontein 1645
Johannesburg
+27 87 3530380
SPAIN
Dometic Spain S.L.
Avda. Sierra del Guadarrama, 16
E-28691 Villanueva de la Cañada
Madrid
+34 902 111 042
+34 900 100 245
SWEDEN
Dometic Scandinavia AB
Gustaf Melins gata 7
SE-42131 Västra Frölunda
+46 31 7341100
+46 31 7341101
Mail: info@dometicgroup.se
SWITZERLAND
Dometic Switzerland AG
Riedackerstrasse 7a
CH-8153 Rümlang
+41 44 8187171
+41 44 8187191
UNITED ARAB EMIRATES
Dometic Middle East FZCO
P. O. Box 17860
S-D 6, Jebel Ali Freezone
Dubai
+971 4 883 3858
+971 4 883 3868
UNITED KINGDOM
Dometic UK Ltd.
Dometic House, The Brewery
Blandford St. Mary
Dorset DT11 9LS
+44 344 626 0133
+44 344 626 0143
Mail: customerservices@dometic.co.uk
USA
Dometic RV Division
1120 North Main Street
Elkhart, IN 46515
+1 574-264-2131
AUSTRALIA
Dometic Australia Pty. Ltd.
1 John Duncan Court · Varsity Lakes QLD 4227
1800 212121 · +61 7 55076001
dometic.com
4445102487 02/2018
CF18-CF60-O-AUS.book Seite 29 Dienstag, 27. Februar 2018 2:14 14

Specifications

Indexed Terms: Fridge Freezer, Fridge

Waeco 9600008649 Questions and Answers

See other models: 9105302047 9105303534