The Combo Washer-Dryer may be installed in a recessed area, closet or alcove.
The installation spacing is in inches and is the minimum acceptable.
Other installations must use the minimum dimension indicated.
Minimum clearances between dryer cabinet and adjacent walls are: 2" either side and 3" front and rear.
Minimum vertical space from floor to overhead cabinets, etc. is 52" (t32cm).
Closet door must be Iouvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open
area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of
120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same with closet with dryer.
-k Additional clearances for wall, door and floor molding may be required.
-k_ Additional space is needed when an external exhaust elbow is used.
NOTE: If a door is installed that potentially encloses the unit while running, the door must
allow for a minimum of 20 square inches of free air movement. There must also be a 1"
space in front of the unit to the closed door and 1" from the back of the unit to the wall.
Additional spacing should be considered for easy installation, servicing and compliance with
applicable local, state, and federal codes.