PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NLC250/NLC250
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts andTurbidity.
Capacity; 250 Gallons (946 Liters)
Service Flow Rate: 0.5 GPM (t,89 L/min,) @60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 1.9 mg/L N/A 0.04 mg/L N/A 97.9% 994707
Particulate N/A 610,000/mL* N/A 154/mL N/A 99.97% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%** 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity 0.5 NTU 29 NTU 0.1 NTU 0.09 NTU 99.5% 99.69% 994710
Lead: @pH 6.5 0.015 mg/L 0.16 mg/L*** 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @pH 8.5 0.015 mg/L 0.16 mg/L*** 0.002 mg/L 0.001 mg/L 96.6% 99.4% 994709
Base Grille Water Filtration System Model WF-LC400/LC400
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity; 400 Gallons (15t4 Liters)
Service Flow Rate: 0.5 GPM (t,89 L/min,) @60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 2.0 mg/L N/A 0.04 mg/L N/A 96% 994707
Particulate N/A 610,000/mL* N/A 154/mL N/A 99% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95%** 89,250/mL* 6/mL 2.3/mL 99.993% 99.997% 994710
Turbidity 0.5 NTU 29 NTU 0.12 NTU 0.09 NTU 99.59% 99.69% 994710
Lead: @pH 6.5 0.015 mg/L 0.16 mg/L*** 0.001 mg/L 0.001 mg/L 99.4% 99.4% 994708
Lead: @pH 8.5 0.015 mg/L 0.16 mg/L*** 0.002 mg/L 0.001 mg/L 96.6% 99.4% 994709
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NLC250 Change cartridge at least every 6-9
months. Use replacement cartridge NLC 250, part# 9902.
2001 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Model WF-LC40O The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400,
part# 9902. 2001 suggested retail price of $39.95 U.S.A./
$49.95 Canada.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Front cover" or Assistance or Service" section
for the Manufacturer's name, address and telephone numben
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application GuidelinesPNater Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33° - 100°F (0.6 ° - 37.8 ° C)
* ** o ***
Test requirement is at least 1OO,OOOparticles/ml of AC Fine Test Dust. Cyst performance is Yoreduction based on NSF Standard 53. Test
o
requirement is O.15 mg/L ± 10 Yo.These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.