Installation
*INSTALLATION*
21
Electrical connection
The appliance is supplied with a mains
cable and moulded plug ready for con-
nection to an AC single-phase 220–
240V50Hz supply.
The fuse rating must be at least 10A.
This appliance must be connected to a
suitable switched socket. The electrical
installation must be in compliance with
current local and national safety regula-
tions, (e.g. VDE0100 in Germany / BS
7671 in the UK). We recommend the
use of a suitable RCD .
The socket must not be concealed be-
hind the appliance and must be easily
accessible so that the appliance can be
quickly disconnected from the electrical
supply in case of an emergency.
If the socket is no longer accessible
after installation, an additional means of
disconnection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole con-
tact gap of at least 3mm. These in-
clude miniature circuit breakers, fuses
and contactors (EN60335).
The mains plug and mains connection
cable must not come into contact with
the back of the appliance as vibrations
can cause damage to these compon-
ents. This could result in a short circuit.
Do not plug in other appliances behind
this appliance.
Do not connect the appliance to the
mains electricity supply by an extension
lead. Extension leads do not guarantee
the required safety of the appliance
(e.g. danger of overheating).
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not syn-
chronised with the mains power supply
(e.g. island networks, back-up systems)
is possible. A prerequisite for operation
is that the power supply system com-
plies with the specifications of
EN50160 or an equivalent standard.
The function and operation of the pro-
tective measures provided in the do-
mestic electrical installation and in this
Miele product must also be maintained
in isolated operation or in operation that
is not synchronised with the mains
power supply, or these measures must
be replaced by equivalent measures in
the installation. As described, for ex-
ample, in the current version of BS OH-
SAS 18001–2 ISO 45001.
If the mains cable needs to be replaced,
this must be performed by a qualified
electrician.