Falmec FNHRZ60I5SS

User Manual - Page 30

For FNHRZ60I5SS.

PDF File Manual, 96 pages, Read Online | Download pdf file

FNHRZ60I5SS photo
Loading ...
Loading ...
Loading ...
28
LIGHTING ASSEMBLY AND REPLACEMENT
I
WARNING! Light bulbs with different shapes and power ratings from the original may seri-
ously damage the light compartment.
1. SPOTLIGHT
How to replace a square halogen light:
a) Check that the equipment is disconnected from the power supply.
b) Open the panel completely till 90° (see figure) pressing the PUSH button
c) Replace the lamp with a similar one (halogen, max 20 W, 12 Volt, G4 connection).
d) Close the panel. If the panel does not close correctly repeat the operation at point b.
Square halogen light
2. FLUORESCENT TUBE
Replacing the fluorescent tube:
a) Disconnect the device from the mains;
b) Unscrew the fixing screws and remove the bottom panel;
c) Remove the fluorescent tube, by rotating through 90°, and replace it with one of similar
features (8W-13W-21W-28W according with the model);
d) Reconnect the device to the mains.
3. LED SPOTLIGHT
In this case the hood is equipped with high efficiency, low power LED spotlights with ex-
tremely high durability under normal use conditions.
MAINTENANCE AND CLEANING
L
Constant maintenance ensures the correct operation and efficiency of the appliance over
time. Special attention should be paid to the metal grease-trapping filters and the charcoal
filters. Frequent cleaning of the filters and their supports will ensure that fats and grease do
not accumulate on the range hood, with the consequent risk of fire.
1. METAL GREASE-TRAPPING FILTERS
These trap the fat and grease particles suspended in the air, and therefore should be
washed every month in hot water and detergent, without bending them. Wait until they
are completely dry before repositioning them. To remove and replace these filters, see
the instructions in point H1. This operation should be performed at regular intervals.
2. ACTIVATED CARBON FILTERS
They have the function of retaining odours in the air flow passing through them. The air,
purified by passing through the filters is re-introduced into the kitchen.
The hood’s active carbon filters can be reactivated by washing them in the dishwasher
with normal detergent at a maximum temperature of 65°C and preferably alone. After
washing, reactivate the filter in an oven at a temperature of 100° C for 30 minutes.
The maximum duration of the filter with an acceptable efficiency is 2/3 years with a
maximum of 10 washings per year.
Loading ...
Loading ...
Loading ...