the filtered air back into your space. For odor control order the optional charcoal filter with your
KBA system.
2. KBA system can be configured to remove air from a sealed space, creating a negative pressure in the
space to allow for fresh air to be exchanged with the ambient air, the filtered air discharged is directed out
of the space. This is achieved with the optional ceiling kit (see section III, paragraph B), or use the factory
supplied flange on the top of the system by connecting duct to the flange and directing it out of the space
(25’ Max). The KBA600 is equipped with an eight inch collar and the KBA1000 is equipped with a ten inch
collar, the KBA can be fitted with a 12” collar for optional ceiling kit use. Note: Reducing the diameter of
the collars or duct will decrease the effectiveness of your system.
C. Apply Electrical Power - Once power is engaged by plugging in your system, your KBA600PLUS
and KBA1000PLUS display will come alive and show the current room temperature. The unit is set to
OFF and the fan is set to high.If your system is not indicating that power is supplied after plugging it
in, refer to the troubleshooting guide in this manual.
D.Apply Electrical Power - KBA600 and KBA1000 once power is engaged, the ON/OFF switch will
display a red light to indicate power is connected. If your system is not indicating that power is
supplied after plugging it in, refer to the troubleshooting guide in this manual.
E. Control Panel for KBA600PLUS & KBA1000PLUS - The control panel display shows the current
operational status of the unit and the current room temperture.
1. ON/OFF Button - Pressing this button on your control panel engages or shuts down
your KBAP system. All settings selected are stored in the microprocessor board even if the
power is lost including the ON/OFF selection. Refer to the Troubleshooting Guide section of
this manual if your KBAP is alerting an alarm after selecting ON.
2. MODE Button - Is not operational in this system. Is displayed above this button.
3. FAN Button-A short press on the FAN button will cycle through the fan speeds. Each press
cycles the fan from low, medium and high, signified by an ascending set of arrows above
the FAN button.