19
HAIKU
®
HOME WWW.HAIKUHOME.COM/SERVICE 1-855-MY-HAIKU
Disconnect power to the fan location before wiring the fan!
Do not connect the fan to a damaged power source! Do not attempt to resolve electrical failures on
your own. Consult a qualified electrician if uncertain of the electrical installation of this fan.
With the fan hanging from the safety cable, connect the fan wires to the ceiling wires by twisting the
ends together and securing them with wire nuts.
If the EMI filter (a) is included, install it with your fan. Test the connection by lightly tugging on the wire
nuts. An EMI filter is an electronic component that suppresses electromagnetic interference.
!
!
5
AC Hot/L1
Brown
AC Neutral/L2
Blue
PE/Earth Ground
(connected to fan chassis)
Green with Yellow Tracer
North America
100–120 V system
Black White Green or Bare Copper
All other regions Brown Blue Green with Yellow Tracer