11
B
E
C
Connect neutral bond wire
and neutral wire
2.
Connect neutral bond wire (E) and neutral wire (white) (C) of
power supply cord under center terminal block screw (B).
Tighten screw.
F
A
3. Connect ground wire
Connect ground wire (F) (green or bare) of power supply cord to
external ground conductor screw (A). Tighten screw.
Connect remaining wires
4.
Connect remaining wires to outer terminal block screws. Tighten
screws. Finally, reinsert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down screw. Now, go to
“Venting Requirements.”
3-Wire Power Supply Cord Connection:
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
3-wire receptacle
(NEMA type 10-30R)
3-prong plug
Spade terminals with
upturned ends
Ring terminals
B
1. Remove center screw
Remove center terminal block screw (B).
2. Connect neutral wire
B
C
Connect neutral wire (white or center) (C) of power supply cord to
center terminal block screw (B). Tighten screw.